ES9160 MFP / ES9170 MFP
© 2012 OKI DATA CORPORATION All rights reserved
DISASSEMBLY AND REPLACEMENT
4 - 98
4.11.2
ADU entrance sensor (S11)
Notes:
After removing the ADU, attach the fixing
band to the holder as shown in the figure.
Fig. 4-273
(1)
Take off the ADU.
(
P. 4-97 "4.11.1 Automatic Duplexing Unit
(2)
Remove 4 screws, disconnect 1 connector,
and then take off the ADU upper guide.
Fig. 4-274
(3)
Release the latches and take off the ADU
entrance sensor.
Fig. 4-275
Fixing band
ADU upper guide
Connector
ADU
entrance
sensor