6 - 16
[C] Image position adjustment of the primary scanning direction
<Procedure>
(1)
While pressing [0] and [5] simultaneously, turn the power ON.
(Adjustment Mode)
(2)
Place a ruler on the original glass with its leading edge pushed against the rear side and its side
along the original scale on the left.
(3)
Press [FAX] -> [START] to make a copy at the mode of A3 (LD), 100% and the lower drawer
(Refer to *).
(4)
Measure the distance B from the left edge of the paper to 10 mm of the copied image of the ruler.
(5)
Check if the distance B is within the range of 10±0.5 mm.
(6)
If not, use the following procedure to change values and repeat the steps (3) to (5) above.
(Adjustment Mode)
(Key in the code [3030])
[START]
(Key in a value (acceptable values: 0 to 255))
Press the [OK] or the [INTERRUPT] button (stored in memory).
(“100% A” is displayed.)
*
The smaller the adjustment value is, the more the image is shifted to the left and the distance
B becomes narrower (0.042 mm/step).
Fig.6-14
50
100
150
200
B
Feeding direction
Copied image of the ruler
Summary of Contents for ES9160
Page 12: ......
Page 24: ...ES9160 MFP ES9170 MFP 2012 OKI DATA CORPORATION All rights reserved FEATURES 1 2...
Page 308: ...ES9160 MFP ES9170 MFP 2012 OKI DATA CORPORATION All rights reserved SELF DIAGNOSIS MODES 5 56...
Page 832: ...ES9160 MFP ES9170 MFP 2012 OKI DATA CORPORATION All rights reserved REMOTE SERVICE 10 38...
Page 920: ...ES9160 MFP ES9170 MFP 2012 OKI DATA CORPORATION All rights reserved BACKUP FUNCTION 12 12...
Page 1086: ......
Page 1087: ......