ES9160 MFP / ES9170 MFP
© 2012 OKI DATA CORPORATION All rights reserved
SETTING / ADJUSTMENT
6 - 44
[A] Installation of the high-voltage transformer jig
The high-voltage transformer jig is composed of 2 cables and 1 adapter with a harness.
Attach them to the process unit as shown in the figure.
*
Black cable (thick line): Use the screw for the jig. (M3 x 8)
*
Red cable (thick line): Use the screw for the process unit.
*
Adapter: Use the screw for the process unit.
Notes:
The adjustment may damage the drum. Therefore be sure to replace the drum with the one that
you brought (or the one for measurement) before starting the adjustment.
Fig.6-21
(1)
Open the automatic duplexing unit.
(2)
Open the front cover and take off the toner
cartridge.
(3)
Loosen 2 screws and pull out the process
unit.
Fig.6-22
Change the drum
Screw
Black cable (thick line)
Harness
Screw
Screw
Adapter
Red cable (thick line)
Disconnect 1 connector
Process unit