ES9160 MFP / ES9170 MFP
© 2012 OKI DATA CORPORATION All rights reserved
ERROR CODE AND TROUBLESHOOTING
8 - 126
Classification
Error content
Scanning system related
service call
The scanning system does not operate due to a blowout of the fuse
in the scanning system.
Proce
dure
Check item
Result
Measure
Next
Step
1
Switching regulator
Check if any fuse in the scanning system is
blown out.
2
SLG board
Check if the conductor pattern on the SLG
board is short circuited or open circuited.
Check if the 24V output and the grounding wire
are normal.
Parts to be replaced
Remark
Fuse in the scanning system
SLG board