4.5.5
Paper stock sensor (S15/S18)
4.5.6
Separation roller
(1)
Take off the drawer feeding unit
(
P. 4-29 "4.5.2 Drawer feeding unit").
(2)
Pull up the paper stock sensor arm.
(3)
Disconnect the connector and release the 3
latches to take off the paper stock sensor.
Fig. 4-82
(1)
Take off the drawer feeding unit
(
P. 4-29 "4.5.2 Drawer feeding unit").
(2)
Remove 1 screw and take off the separation
roller holder.
Fig. 4-83
(3)
Detach the lever from the holder and take off
the separation roller with the shaft.
Fig. 4-84
Paper stock sensor
Separation roller holder
Lever
Separation roller