4
© 2012 OKI DATA CORPORATION All rights reserved
ES9160 MFP / ES9170 MFP
DISASSEMBLY AND REPLACEMENT
4 - 59
4.7.11
Recovery blade
4.7.12
Ozone filter
(1)
Take off 3 drum separation finger units
(
P. 4-58 "4.7.10 Drum separation finger").
(2)
Remove 2 screws, and take off the whole
recovery blade with the bracket.
Notes:
When cleaning the inside of the cleaner unit,
be careful of the following in order not to
damage the films attached on the toner
recovery auger:
1. Do not use an air blower for cleaning.
(Use a vacuum cleaner.)
2. When using a vacuum cleaner, be careful
not to hit the nozzle of the vacuum
cleaner to the films.
3. When rotating the toner recovery auger,
rotate it only in the same direction as that
for transporting toner.
Fig. 4-162
Fig. 4-163
(1)
Open the automatic duplexing unit.
(2)
Lift up the transfer unit.
Fig. 4-164
Recovery blade
Film
Toner recovery auger
Transfer unit