- 156 -
8.117 ^RZ SET RFID TAG PASSWORD AND LOCK TAG
Format: ^RZp,m,l
p = Password
00000000 to FFFFFFFF
When omitted: None
* If this parameter and the AccessPassword set in the tag do not match, void printing is performed.
m = Memory bank
K : Kill password
A : Access password
E : EPC
T : TID
U : USER
When omitted: None
l = Lock type
U : Unlock
L : Lock
O : Permanent unlock (unsupported)
P : Permanent lock
W : Writing (unsupported)
* This parameter is ignored.
When omitted: None
(If the lock type setting is omitted, the setting of parameter p is invalid.)
*1 Whenever tag is locked, AccessPassword is required to be set.
Set it with RFW or RQ command.
*2 Due to the specification of GEN 2 tags, they cannot be locked if AccessPassword consists of all
zeros.
*3 Although multiple settings are allowed between XA and XZ, OkiData writes data on tags at one
time and the lock type set last for each bank becomes valid. On the other hand, Zebra writes data
in the order of registration.
Lock types L and P cannot coexist. The lock type set last is valid.
*4 Enabled only when U2 module is installed.