- 39 -
8.7 ^B9 UPC-E BAR CODE
Format: ^B9o,h,f,g,e
o = Font rotation
N : 0°
R : 90°
I : 180°
B : 270°
When omitted: Value of ^FW
* The point of origin differs depending on the coordinate designated in ^FT and ^FO.
h = Bar code height (in dots)
203-dpi printer: LE840
1 to 800 dots
300-dpi printer: LE850
1 to 1200 dots
When omitted: Value of ^BY
*1 If the value after dot-to-mm conversion exceeds 100 mm, it is corrected to 100 mm.
*2 If 0, a string, or other value is selected, it is corrected to 10 dots.
f = Print interpretation line
Y : Printed
N : Not printed
When omitted: Y
g = Print interpretation line above code
Y : Printed
N : Not printed
When omitted: N
e = Print check digit
Y : Printed
N : Not printed
When omitted: Y
*1 The character type of the interpretation line is switched depending on the set value for the module
width of ^BY.
In the case of 203-dpi printer
Module width is 2 or less: Font A
Module width is 3 or more: Font E
In the case of 300-dpi printer
Module width is 4 or less: Font A
Module width is 5 or more: Font E
*2 Data other than numeric values, if any, are converted to ‘0.’
*3 When the interpretation line above code is to be printed with Oki Data, the header and terminator
(system number and check digit) are printed outside the guide bar.
In the case of Zebra, the interpretation line above code is printed at the center between the guide
bars.
*4 If the number of digits in data is 7 or 8;
Oki Data: The data is reduced to 6-digit data by deleting the header.
Zebra:
If the header is ‘1’, 7 digits from NS constitute the data.
If the head data is not ‘1,’ the data is reduced to 6-digit data by deleting the header.
*5 To print the interpretation line above code, the interpretation line parameter (parameter f) needs to
be set to “Y.”
*6 If the command is sent without setting data (only ^FS and ^XZ are set while ^FD^FS and ^FD are
not set), the barcode will not be printed.