- 35 -
correspondence with the “Font Conversion Table.”
Since the information in the “Font Change Table” is exclusive for ^CW, it cannot be used here.
*3 If the font name is improper or omitted, set the font type with the following procedure:
In the case the font name is omitted:
If a valid font name is already set with A@ command, the font previously printed with A@
command is used. If a valid font name is not specified in A@ command, the font specified
in CF command is used.
In the case the font name is improper:
If a valid font name is already set with A@ command, Font 0 is used. If a valid font name
is not specified in A@ command, the font specified in CF command is used.
8.3 ^B2 INTERLEAVED 2 OF 5 BAR CODE
Format: ^B2o,h,f,g,e
o = Font rotation
N : 0°
R : 90°
I : 180°
B : 270°
When omitted: Value of ^FW
* The point of origin differs depending on the coordinate designated in ^FT and ^FO.
h = Bar code height (in dots)
203-dpi printer: LE840
1 to 800 dots
300-dpi printer: LE850
1 to 1200 dots
When omitted: Value of ^BY
*1 If the value after dot-to-mm conversion exceeds 100 mm, it is corrected to 100 mm.
*2 If 0, a character string, or other value is selected, it is corrected to 10 dots.
f = Print interpretation line
Y : Printed
N : Not printed
When omitted: Y
g = Print interpretation line above code
Y : Printed
N : Not printed
When omitted: N
e = Calculate and print Modulus 10 check digit
Y : Printed
N : Not printed
When omitted: N
*1 Data other than numeric values, if any, will be deleted.
*2 When data are set with ^SN and the parameter z of ^SN (add leading zeros) is N, ‘0’ at the
beginning of data will be deleted.
*3 To print the interpretation line above code, the interpretation line parameter (parameter f) needs to
be set to “Y.”
*4 The character type of the interpretation line is independent of the module width value of ^BY. Font