Page: 20
Service Guide ML390/391
Chapter 2 Principles of Operation
2.3 ELECTRICAL OPERATION
2.3.01 Initialization
Initialization occurs whenever the printer is powered ON or when the signal I-PRIME is received at the
parallel interface.
The initialization sequence is as follows.
· Q6, Q8, and Q11 are reset.
· The operating modes of Q6, Q8, and Q11 are set.
· Memory (ROM and RAM) is checked.
· RAM is initialized.
· Carriage homing is performed. The carriage will move to the left until it contacts the left frame.
· The program establishes the interface signals (ACK, BUSY) and the SEL lamp lights.
Copyright 1997, Okidata, Division of OKI America, Inc. All rights reserved. See the OKIDATA Business
Partner Exchange (BPX) for any updates to this material. (http://bpx.okidata.com)
Summary of Contents for MICROLINE Turbo ML390