MSM9225B User’s Manual
Chapter 3 Operational Description
3 – 5
3.1.5 Remote Frame Operation
The following two methods are available for transmission after remote frame reception.
(1) Automatic response: automatically transmit preset message data in message box
(2) Manual response: set message data and then transmit
3.1.5.1
Automatic Response
After remote frame reception, this method automatically transmits preset message data in message box.
Table 3-1 lists the settings of the message control register.
Table 3-1 Message Control Register Settings for Automatic Response
Bit
Symbol
Value
Comments
Bit 5
TRQ
0
When reception is complete, TRQ bit changes from 0 to 1.
Bit 3
EIR
0/1
To enable receive interrupts, set this bit to “1”.
Bit 2
EIT
1
Set interrupt to verify the end of transmission.
Bit 1
FRM
0
Specify remote frame as the receive frame type.
Message
control register
(x0hex)
Bit 0
ARES
1
Set automatic response.
Figure 3-5 is the operation flowchart.