MSM9225B User’s Manual
Chapter 3 Operational Description
3 – 7
3.1.5.2
Manual Response
In this method, after remote frame reception, the transmit data is set and then transmission begins.
Table 3-2 lists the settings of the message control register.
* See Appendix C “Transmission Failure of MSM9225B” for transmission operation.
Table 3-2 Message Control Register Settings for Manual Response
Bit
Symbol
Value
Comments
Bit 5
TRQ
0
Set to receive message box.
Bit 3
EIR
1
Set interrupt to verify (remote frame) reception.
Bit 2
EIT
1
Set interrupt to verify the end of transmission.
Bit 1
FRM
0
Specify remote frame as the receive frame type.
Message
control register
(x0hex)
Bit 0
ARES
0
Specify that automatic response is disabled.
Figure 3-6 is the operation flow chart.
The basic operation is a combination of receive and transmit procedures.