4-18
R.4.2
A
MPS/EOM/EOP was not received. Either the line disconnected
before reception was completed or too many errors were detected
by the receiving unit. Adjust the data error rate on Memory Switch
C:0. It may also be necessary to decrease the receive
communication speed via Memory Switch C:0.
R.4.4
E
The receiving fax machine has reached its memory capacity.
R.5.1
A
DCN was received instead of RR during ECM communication.
R.5.2
A
Line noise or other problems prevented ECM reception.
*: See “Communication Error messages” on next page.
Transmission errors
Error code
Message *
Explanation
T.1.1
A
T1 time-out. The remote fax machine didn’t respond to your
machine. This usually occurs during a manual transmission or when
an incorrect number was dialled. Call someone at the remote
machine.
T.1.4
G
The STOP button was pressed during transmission.
T.2.1
A
CFR or FTT was not received from the remote machine. Either the
phone line disconnected during fax communication or transmission
became impossible due to bad phone line conditions. Try the call
again. It may be necessary to increase the output levels on
Machine Parameter A:1. The receive machine may also have
closed network or block junk fax enabled.
T.2.2
A
The two fax machines were incompatible. No mailbox at receiver or
security transmission is enabled.
T.2.3
A
FTT was received from the remote machine at 2400 bps. Bad
phone line conditions made fax communication impossible.
Conditions can change rapidly, so try the call later. Turn on the
echo protect tone on Memory Switch B:0. Also adjust the interval
between DCS and TCF on Memory Switch B:1. If the problem
persists, try increasing the output levels on Machine Parameter A:1.
T.3.2
A
The fax machine didn’t detect the silence period for ending channel.
T.4.1
No response to MPS/EOP/EOM. Poor phone lines caused the
receiving unit to disconnect. Adjust the interval between CFR and
data on Memory Switch B:1. Try increasing the output levels on
Machine Parameter A:1. It may also be necessary to adjust the
transmit speed on Memory Switch B:0.
T.4.2
D
RTN was received from the remote machine. After transmission
began, poor line conditions developed. Try the call again. Attempt
the solutions described for the T.4.1 error.
T.4.4
B
Poor line conditions prevented transmission. PIP was received. The
transmission was interrupted by the call mode. The receiving unit
may be experiencing problems. Try the call again.
T.5.1
A
No response to RR from the remote machine. Line noise or other
problems prevented ECM transmission. Increase the ECM
response time on Memory Switch B:2.
T.5.2
A
No response to CTC. Line noise or other problems prevented ECM
transmission. Increase the ECM response time on Memory Switch
B:2.
T.5.3
B
EOR was received from the remote unit but further transmission
was not possible. Adjust Memory Switch B:5 for this problem.
*: See “Communication Error messages”.
Summary of Contents for OKIOFFICE 120
Page 7: ...vi ...
Page 17: ...1 10 1 7 Dimensions Dimension in mm ...
Page 23: ...1 16 1 11 ID Label Specification 1 12 Labels location ...
Page 24: ...2 1 Section2 Machine Composition 2 1 Interconnect Block Diagram ...
Page 25: ...2 2 ...
Page 87: ...3 46 Unique Switch F 7 and F 9 Factory use only ...