3-32
3.7 Unique Switch Adjustment
3.7.1 Setting the Unique Switches
These switches are used to program internal machine parameters. The primary back up battery
maintains these settings if power is lost.
1. From standby, press PROGRAM, *, 4.
Set Uniq Switch
Program/Enter
2. Press ENTER.
A0: 01000001
Program/Enter
3. Select the desired unique switch by pressing a one-touch key plus a number on the keypad. For
example, to access parameter B:1, press one-touch “B” plus the number “1” on the numeric
keypad.
B1: 00000000
Program/Enter
4. Press ENTER.
Set Uniq Switch
B1 00000000
Bit No. 76543210
(The bits are numbered 7 through 0 --- bit 7 is left most.)
5. To navigate through the unique switch settings:
•
Press
key to move the cursor to the left.
•
Press
key to move the cursor to the right.
•
Press the 0 or 1 on the numeric keypad to change the bit value.
•
Press ENTER to save the setting of the displayed unique switch and advance to the next
unique switch.
(Continue pressing ENTER until the desired unique switch is shown in the display. Be sure to
press ENTER after each unique switch is programmed to save the new setting.)
•
Press STOP to return the unit to standby.
Clearing the Unique Switches
Resets the unique switches to factory defaults.
1. From standby, press PROGRAM, *, 4, PROGRAM.
Clear Uniq Switch
Program/Enter
2. Press ENTER.
Clear Uniq Switch
Check Program/Enter
3. Press ENTER. The unique switches will reset to factory defaults.
Note: To finish the operation without clearing the unique switches, press STOP or PROGRAM.
Summary of Contents for OKIOFFICE 120
Page 7: ...vi ...
Page 17: ...1 10 1 7 Dimensions Dimension in mm ...
Page 23: ...1 16 1 11 ID Label Specification 1 12 Labels location ...
Page 24: ...2 1 Section2 Machine Composition 2 1 Interconnect Block Diagram ...
Page 25: ...2 2 ...
Page 87: ...3 46 Unique Switch F 7 and F 9 Factory use only ...