40496501TH Draft Version
93
Item No. Items
Standard Value
Illustration
Adjustment Method
Correct the printing alignment in each
"Registration1 ....7". (Note2)(Note3)
Note2)After printing, change items with
4
switch
Note3)The reverse printing position is
shifted by 0.05mm to the reference
position by pressing
4
switch or
8
and
4
switch.
4
After completing the correction,
press
6
switch to store the corrected
values to the inside of printer. (Note4)
Note4)If the
6
switch is not pressed,
the corrected values cannot be stored
and the settings are returned to the
previous set values.
Press
5
while holding
8
to print a
menu page to check the registration.
(See the left drawing)
Number
+5
+4
+3
+2
+1
0
-1
-2
-3
-4
-5
Correction dot position of reverse printing
Printing position is shifted by 0.25mm to right of the reference position.
Printing position is shifted by 0.20mm to right of the reference position.
Printing position is shifted by 0.15mm to right of the reference position.
Printing position is shifted by 0.10mm to right of the reference position.
Printing position is shifted by 0.05mm to right of the reference position.
Reference position
Printing position is shifted by 0.05mm to left of the reference position.
Printing position is shifted by 0.10mm to left of the reference position.
Printing position is shifted by 0.15mm to left of the reference position.
Printing position is shifted by 0.20mm to left of the reference position.
Printing position is shifted by 0.25mm to left of the reference position.
4
8
and
4
Summary of Contents for PACEMARK 4410
Page 1: ...PACEMARK 4410 PRINTER SERVICE HANDBOOK...
Page 52: ...40496501TH Draft Version 52 Figure 3 1 3 2 Parts Layout...
Page 95: ...40496501TH Draft Version 95...
Page 168: ...XXXXXXXXTH Draft Version 8 5 Fig 8 5 45 38 38 40 42 39 44 44 122 41...
Page 169: ...XXXXXXXXTH Draft Version 8 6 142 141 11 119 Fig 8 6...
Page 170: ...XXXXXXXXTH Draft Version 8 7 Fig 8 7 105 102 61 33 104 100 101...