Page: 48
Service Guide OL830
Chapter 3 Maintenance & Disassembly
3.3.02 Modified Page Count
The modified page counter combines the main motor revolution time and the number of printed
sheets. Drum replacement is determined by the modified page count. Follow these steps to check
the modified page count.
NOTE:
To access the Modified Page Count, you must first view the Actual Page Count.
1. After viewing the Actual Page Count, press Switch 1 for five seconds. The LED will display the
contents of the Parameter 1 (Modified Page Count) register.
2. To end this procedure, press Switch 1 for one second. The LED will perform one short flash to
indicate Parameter 1 is selected.
Example
Modified Page Counter = 142
Switch 1 Action
LED Display
Description
Press for five
seconds
Long Flash
Start of Modified Page
Count
None
On-Off-Pause
1st Digit = 1
None
On-Off-On-Off-On-Off-On
-Pause
2nd Digit = 4
None
On-Off-On-Off-Pause
3rd Digit = 2
None
Long Flash
Start of Count
Press for 1
second
Flashes ON/OFF
Parameter #1 -
Selected
NOTE:
The number "0" is represented by 10 flashes
The Actual and Modified Page Counters cannot be changed.
Copyright 1997, Okidata, Division of OKI America, Inc. All rights reserved. See the OKIDATA Business
Partner Exchange (BPX) for any updates to this material. (http://bpx.okidata.com)