background image

12

Safety features

• 

The fluid reservoir tank has a built-in sensor. This will shut off the machine automatically  

 

when the tank is full, to prevent any damage. This will happen when there is approx. 350 ml  

 

of fluid in the tank. Please empty tank as described above. 

Note: make sure that you have switched off the vacuum motor, as the machine could start 
to vacuum automatically should the sensor reset while you are emptying the tank. Da-
mage to the machine could occur if this happens. 

The machine will be ready for use once the 

tank is emptied. However, the standard drain down procedure, i.e. after 20-30 LP’s is the preferred 

method.

• 

The vacuum motor has a built-in temperature sensor. If the internal temperature of the  

 

machine becomes too high, it will cause an automatic shut down. In this case, please switch  

 

the machine completely off and 

wait at least 30 minutes

 before using it again

Useful hints and recommendations

• 

Keep your RCM clean! Mop up any excess fluid that goes onto the top off the unit.

• 

Rinse out the cleaning brush in warm water. Avoid any  build up of dirt.

• 

Maintain the velvet strips on the vacuum tube. Regularly check for  dirt, wear and damage.  

• 

Make sure there is no build up of debris and after each cleaning session,  brush off with your  

 

finger or a soft child’s toothbrush, is ideal. Change strips after approx. 200 sides – more 

 

often if required.

• 

Really old and dirty records will benefit from being cleaned several times.

• 

Always replace the inner sleeve, the FIRST time you clean a record.

• 

We recommend the use of Okki Nokki’s specialized cleaning concentrate.

• 

NEVER use a cleaning fluid that contains more than 25% alcohol.

• 

NEVER use an alcohol based fluid on 78s, shellac or acetates.

• 

NO naked flames or smoking when using alcohol based mixes. Danger !!

• 

Always ventilate when using alcohol based mixes.

• 

We recommend the use of a separate vacuum tube when cleaning 78s.

• 

Never take out the vacuum arm tube while the machine is switched on. This can severely  

 

damage the machine. 

• 

Always use recommended cleaning fluids. Do not use excessive alcohol mixes. Do not use  

 

foaming type cleaning fluids.

Accessories for your Okki Nokki

7”,10” and 12” vacuum tubes, record cleaning fluid, replacement velvet strips, wood brush with vel-

vet strip for pre-cleaning LP’s, application brush, dustcover.

Maintenance

The turntable should be cleaned regularly with a household vacuum cleaner. Wipe the surface 

clean with a damp cloth.

From now on, your records will sound Okki Nokki!

Owner’s Manual

Summary of Contents for Record Cleaning Machine

Page 1: ......

Page 2: ......

Page 3: ...soires Bijgeleverd zijn een standaard afzuigarm een applicatieborstel een flesje reinigingsvloeistof een platenklem en een geaard netsnoer NB het flesje reinigingsvloeistof is een concentraat en dient...

Page 4: ...ergelijk geval komt de garantie per direct te vervallen Reinigingstest Wij bevelen een testronde aan op een oude onbelangrijke elpee om er zeker van te zijn dat de machine goed is ingesteld en juist w...

Page 5: ...g de zuigarm rich ting achterzijde van het apparaat en zet de motor van het plateau uit Onthoud goed zet eerst de zuigmotor uit en dan de motor van het plateau Verwijder de klem draai de elpee om en h...

Page 6: ...de strips na circa 200 kanten en vaker indien noodzakelijk Zeer oude en vervuilde elpees dienen meerdere malen een schoonmaakbeurt te krijgen Vervang altijd de binnenhoes van een elpee bij de eerste...

Page 7: ...Neem contact op met uw dealer indien de machine niet meer of onjuist werkt Open onder geen enkele omstandigheid de machine om zelf reparaties uit te voeren of op andere manier wijzigingen aan te bren...

Page 8: ......

Page 9: ...bottle of cleaning fluid is a concentrate and requires mixing with a liter of purified water not battery or steam iron top up not tap water but purified water which is available from most chemists Wh...

Page 10: ...practice run on an old unwanted LP in order to ensure that the machine is set up and working correctly and to acquaint yourself with the correct cleaning procedure Cleaning operation Place the record...

Page 11: ...and now repeat the process on side 2 Emptying the cleaning liquid reservoir After having cleaned 20 30 LPs the waste liquid has to be drained from the reservoir Failure to drain the reservoir on a reg...

Page 12: ...dirt wear and damage Make sure there is no build up of debris and after each cleaning session brush off with your finger or a soft child s toothbrush is ideal Change strips after approx 200 sides more...

Page 13: ...nsible manner as advised in this manual Should the machine fail to operate please contact your dealer Under no circumstances must you open the machine and attempt repairs or alter the machine in any w...

Page 14: ......

Page 15: ...ne Fl schchen Reinigungskonzentrat wird mit 1 Liter destilliertem Wasser verd nnt Die gemischte Fl ssigkeit sollte an einem dunklen und k hlen Platz aufbewahrt werden Das kleine Fl schchen in dem das...

Page 16: ...mit der schwarzen Kappe sicher verschlossen ist WARNUNG Benutzen Sie niemals die Maschine ohne die sicher verschlossene schwarze Kappe Reinigungstest Wir empfehlen Ihnen einen Testdurchlauf an einer...

Page 17: ...Schallplatten besch digen Schalten Sie den Saugmotor aus und heben Sie den Arm gleichzeitig an Drehen Sie nun den Ab saugarm wieder zum Rand der Plattenwaschmaschine zur ck Bei stark verschmutzten Sch...

Page 18: ...dort nur wenig oder gar keine Fl ssigkeit vorhanden ist Dies kann folgende Ursache haben Sie verwenden eine Mischung auf Alkoholbasis die dazu neigt durch die W rme die von der Maschine entsteht zu v...

Page 19: ...nd 12 Absaugarme Reinigungsmittel Samtstreifen B rste Haube Wartung Der Drehteller sollte regelm ig mit einem herk mmlichen Hausstaubsauger abgesaugt werden Reinigen sie das Geh use mit einem feuchten...

Page 20: ...20 Zubeh r f r die Okki Nokki Reinigungsfl ssigkeit 10 inch und 7 inch Absaugarme Ersatzreini gungsstreifen B rste Haube Bedienungsanleitung...

Page 21: ......

Page 22: ...nettoyage liquide de nettoyage fixation ronde du disque c ble avec prise de terre Merci de bien noter que le petit fla con de liquide de nettoyage est un concentr et n cessite un m lange avec un litr...

Page 23: ...e le tube plastique de drainage l arri re de la machine est en position ferm e avec le bouchon noir en place Avertissement ne jamais utilisez la machine sans le bouchon noir en place En aucun cas vous...

Page 24: ...r tout absorber En proc dant davantage de tours vous pourriez endommager votre disque teignez le bouton d aspiration et le bras se soul ve automatiquement gr ce au res sort int gr dans le bras Tournez...

Page 25: ...ev e la machine se coupe automatiquement Dans ce cas teignez compl tement la machine et attendez au moins 30 minutes avant de la r utiliser Recommandations et conseils pratiques Maintenez votre machin...

Page 26: ...perdez la garantie sur cette machine si vous ne suivez pas la proc dure d utilisation de cette machine de mani re responsable Si la machine ne fonctionnait pas contacter s v p votre distributeur En au...

Page 27: ......

Page 28: ......

Page 29: ......

Page 30: ......

Page 31: ......

Page 32: ......

Page 33: ......

Page 34: ......

Reviews: