Chapter 4 Maintenance of Mechanical Components
34
Document Version V1.1.2 (19/09/2022)
When removing the base interface panel, do not forcibly pull
it to avoid damage to cables.
Installation
Tools: 2 mm Allen wrench, H2.5 * 50 torque wrench (1-5 N·m).
Screw type: hexagon socket countersunk head screw (M3 * 8)
Step 1
Arrange wires and cables in the base, and connect the disconnected
connectors and ground terminal on the controller in the upper control
cabinet.
Step 2
Hold the base interface panel by aligning with the screw holes on the robot
body, and then use 2.5 mm Allen wrench to tighten the fastening screws on
the base interface panel of the robot (with a tightening torque of 0.5 N·m) ,
as shown in Figure 4-13.