5
3
Safety Notes
In order to achieve maximum performance and to ensure proper operation of your new equipment, please
read carefully the following safety notes and the instructions. If you have any question, please contact Okolab.
−
The equipment must only be used as intended and as described in this Manual.
−
Equipment should be operated only by technically qualified personnel.
−
Do not start up the equipment if some of its parts are damaged.
−
This instrument is not intended for use in locations subject to flammable or explosive gases.
−
Transport the equipment with care.
−
Equipment and its internal parts can be damaged by dropping and by shock.
−
Not following these instructions can result in damage or breakdown of the device and its
accessories.
−
The products labels can be found on the bottom panel of the Main Unit.
−
Do not disassemble any part of the system.
−
Do not disconnect cables while in operation.
−
Do not use a volatile solvent such as paint thinner to clean the instrument because deformation
or discoloration may occur.
−
Use a soft, dry cloth to remove stains from the instrument.
−
Do not exceed voltage indicated in this manual and on the product label.
−
Avoid excessive induction noise, static electricity and magnetic fields.
−
Do not expose this instrument to rain or moisture.
−
Do NOT go in close contact with or breathe any gas stream whose composition is different from
that of ambient air.
−
Prevent throttling and kinking of tubing.
−
Check tubing time to time for possible material usage.
−
Check that all tubing is well inserted into the connectors so they cannot slip off
−
This device is not designed for use for medical applications.
−
Install safety valves and adequate pressure regulators on gas lines before the CO2 Controller
input connectors.
−
Power cord of unit should be unplugged from electrical outlet when left unused for a long period
of time.
−
PRESSURIZED GAS, secure all connections with hose clamps. Never exceed pressure limits, 1.5
Bar. Bleed all lines before disconnecting. Wear safety goggles if needed. If pressure regulators
are not within sight and reach make sure at least one shut off valve within reach.
−
LOW OXYGEN ATMOSPHERES, never enter a room or enclosure which has a low oxygen
atmosphere because of severe danger of suffocation. Only operate in well- ventilated room. A
small amount for carbon dioxide gas leaks continuously out of the instrument and should never
be allowed to build up in room.