13.11 Motor extraction auger 1 - RA (Fault 5026)
Display:
[5026] Motor ext auger1
Description:
Storage room auger 1 motor defect – Output RA
Cause and Remedy:
Motor unplugged
ڃ
Plug in motor, check cable connections
motor is jammed
ڃ
Remove pellets and dust from auger and
make sure auger rotates freely
Motor defect
ڃ
Replace motor
Thermic contact triggered
ڃ
Let motor cool down
Motor not running
ڃ
Check thermic contact
13.12 Hopper motor (Fault 5028)
Display:
[5028] Hopper motor
Description:
Hopper suction fan fault. Output ZW.
Cause and Remedy:
Motor unplugged
ڃ
Plug in motor, check cable connections
Motor defect
ڃ
Replace motor
13.13 Emergeny OFF/ Safety temperature (Fault 5032, 5033)
Display:
[5032] Emergeny OFF – NOT AUS
Description:
Emergency OFF has been actuated – Input NOT-AUS
Cause and Remedy:
Emergency OFF
unplugged
ڃ
Connect up Emergency OFF and check cab-
le connections
Emergency OFF button
has been pressed
ڃ
Reset Emergency OFF switch
Emergency OFF defect
ڃ
Replace Emergency OFF switch
Display:
[5033] Safety temperature - STB
Description:
Safety temperature limiter has tripped – Input STB
Cause and Remedy:
Safety temperature limiter
unplugged
ڃ
Connect up safety temperature limiter and
check cable connections
Safety temperature limiter
has tripped
ڃ
Let boiler cool down and reset safety tem-
perature limiter
Safety temperature limiter
defect
ڃ
Replace safety temperature limiter
A 230V Output is defect
ڃ
Check 230V Outputs
13.14 Temperature Combustion chamber sensor/Flue gas sensor (Fault 5034, 5036)
Display:
[5034] PE Ignition fault / Pellets available?
Description:
Minimum temperature Combustion chamber sensor/Flue gas sensor not rea-
ched durring the ignition phase
Cause and Remedy:
No pellets available
ڃ
Fill up with pellets
Ignition electrode defect
ڃ
Check ignition electrode (approx. 200
ˑ
) re-
place if required
Ignition nozzle blocked
ڃ
Clean burner plate and ignition tube
Operating Manual PELLEMATIC® PE(S)(K)(B) 10 — 56
Summary of Contents for PE 08
Page 16: ...16 Wiring diagrams PE 567 EN 1 1 ...
Page 17: ...Wiring diagrams 17 Operating Manual PELLEMATIC PE S K B 10 56 ...
Page 18: ...18 Wiring diagrams PE 567 EN 1 1 ...
Page 76: ...76 Code Input Menu of Pelletronic Touch after entering the code PE 567 EN 1 1 ...
Page 110: ...110 Cascade settings Back to the menu Sys Regulation PE 567 EN 1 1 ...
Page 168: ......
Page 169: ......