background image

OKRA

4

Summary of Contents for 07

Page 1: ...07 Quick Guide Manual Blood Glucose Monitoring System ...

Page 2: ......

Page 3: ...07 Quick Guide Manual Blood Glucose Monitoring System ...

Page 4: ...OKRA 4 ...

Page 5: ...OKRA 5 Twist the cap to the displayed arrow direction Gently pull the cap to remove Insert the lancet into the lancet holder push it all the way in Using your lancing device ...

Page 6: ...OKRA 6 Twist and remove the protective cap from the lancet to expose the needle Place the cap back on your lancing device Twist the cap to the direction as shown in arrow ...

Page 7: ...5 6 1 3 5 Select the depth of the lancet by dialing the lancing device Setting of the lancing depth begin on one for the shallowest setting Increase the dial if more depth is needed Pull the handle out until it clicks ...

Page 8: ...n date 125 Always wash and dry your hands before and after you perform a blood glucose test Remove a test strip from the test strip container Close the cap tightly 125 125 Level 1 Level 2 Level 3 CONTROL RANGE mg dL Blood Glucose Test Strips INFS001LF ISC02659 TEST STRIPS Made in Korea Rev 2020 10 01 REF Distributed by CGETC Inc CITY OF INDUSTRY CALIFORNIA 91748 LOT Expiry date Discard date CODE E...

Page 9: ... glucose in capillary whole blood For In Vitro Use Only Store in a cool and dry place between 36 86 F 2 30 C Do not Refrigerate Do not Freeze Discard 6 months after opening Do not use after expiration date 125 Hold the lancing device firmly against the edge of your fingertip and press the release button to prick your finger Always check to see whether the code number on the meter display and the c...

Page 10: ...he blood insert icon on your meter touch the end of the test strip to the blood drop Do not apply blood on top of the test strip Caution Inserting blood at the end of the test strip Do not put blood on TOP of the test strip ...

Page 11: ...OKRA 11 The test result appears on the display after 5 seconds Dispose the used strip by pushing the ejector ...

Page 12: ...32 INFM001LF Rev 2020 10 01 REF Tel 833 977 1339 www okra care S N Blood Glucose Monitoring System Model IGM 1003 Rating 3V 4mA MadeinKorea IMC01932 INFM001LF Rev 2020 10 01 REF Tel 833 977 1339 www okra care S N Open the battery door by pushing the tab toward the door and pull the door up and open Release the old battery and replace with a new battery with the plus sign facing up Replace the batt...

Page 13: ...OKRA 13 Blood Glucose Monitoring System Trouble Shooting ...

Page 14: ...e check to see if the test strip has already been used To solve this issue please take out a new test strip from the container and insert into the meter When blood insert icon appears please apply blood sample at the end of the test strip Error Code_Er2 ...

Page 15: ...is issue make sure to insert the blood at the end of the test strip not on top of the test strip When you see Er3 on the meter display please check whether enough blood has been inserted into the test strip Error Code_Er3 ...

Page 16: ...ther the strip has been inserted after the blood insert icon has appeared To solve this issue please take out a new test strip from the container and insert into the meter Make sure the blood insert icon has appeared before applying the blood sample Error Code_Er5 ...

Page 17: ...OKRA 17 Memo ...

Page 18: ...OKRA 18 Memo ...

Page 19: ......

Page 20: ... Inc CITY OF INDUSTRY CALIFORNIA 91748 Quality Guarantee www okra care Customer service is available Monday thru Friday 9 to 5pm Eastern Time TEL 833 977 1339 E MAIL support okra care Rev 2021 07 01 IMC01933 INFM001LF REF ...

Reviews: