Maintenance operations have to be carried out by 

specialized and authorized personnel

.

Do not  

violate

 

for  any  reason at  all  

the safety devices  

the unit   is equipped with,  like the high

pressure valve of the internal reservoir.

Do not

 fill compressed air in the lines of the service unit or in the vehicle aircon system (a mixture of

air and refrigerant can be flammable or explosive); 

Please be aware that whatsoever damages due to a wrong or improper use of the recharging station will not
be covered by our warranty. Consumables like packing and seals for hoses and quick couplings, fuses and
damages occurred during transport are not part of the warranty.

1.2.1 Warning icons used in the present manual

Caution!

Connect to

230V socket

50Hz

Wear gloves

when handling

refrigerants

Wear goggles

when handling

refrigerants

Protect against

rain

Read

instruction

manual

carefully

1.2.2 Safety devices

A) Pressure release valves on internal gas tank:  releases pressure if 16 Bar are exceeded in the gas tank.

1.3 Scrapping of the unit

-

 Do not treat the unit as mixed solid waste for scrapping but take it to pieces ( waste separation).

- Refer to the specific collection points for waste of electric and electronic devices (AEE), according to the
relevant 

CEE RAEE 2002/95/EC, 2002/96/EC2003/108/EC

 regulation.

- The vacuum pump and the containers of new and used oil contain mineral and synthetic oil. Therefore the
specific  regulations  for   scrapping   have  to  be  followed.  The  same  procedure  has  to  be  followed  for  the
refrigerant gas residual in the storage bottle. The exhaust oil drained from the pump is a specific waste and
has to be collected according to the relevant regulations in force.

Ecos-150  sw  1.x.x  - ver. 1.0            

    

Page 4/20

Summary of Contents for ECOS-150

Page 1: ...Use and Instruction Manual Ecos 150 sw 1 x x ver 1 0 Service station for A C systems ECOS 150...

Page 2: ...Analytical description of the working cycles 10 3 4 1 Model choice through the internal DATABASE 10 3 4 2 MANUAL AUTOMATIC mode 10 3 4 2 1 Starting an automatic working cycle 11 3 4 2 2 Recovery 11 3...

Page 3: ...0X Ecos20X HFO 1234YF for Fast20XYF Do not make modifications to the service unit Only employ original spare parts and accessories Use authorized additives or consumables only ask for advice from an a...

Page 4: ...handling refrigerants Wear goggles when handling refrigerants Protect against rain Read instruction manual carefully 1 2 2 Safety devices A Pressure release valves on internal gas tank releases press...

Page 5: ...first time remove the safety screw which is screwed to the tank load cell for protection during transport see fig 1 It is recommended to check the regular functioning of the load cell for example by h...

Page 6: ...the gas residuals in the A C system of the vehicle at the en of the working cycle Note in case of a pressure test which is not preceded by a standard working cycle the user has to recover the gas resi...

Page 7: ...t used by the A C system to be serviced is the one the service unit is intended for R134a Check oil levels vacuum pump and new oil reservoir After having turned on the unit check the level of the refr...

Page 8: ...databank update 9 Button EXIT To select and confirm the different functions or to enter the following menu 10 Button ENTER Interrupts any whatsoever operation to exit and return to the previous menu 1...

Page 9: ...ease of Non Condensable Gases If the value of the theoretical gas pressure see above point c calculated on the base of the gas temperature measured by the temperature probe is significantly higher tha...

Page 10: ...ycles and press ENTER in order to perform that particular cycle only 3 4 2 MANUAL AUTOMATIC mode Select MANUAL in order to reach the working cycle selection All working cuclescycles can be done automa...

Page 11: ...igh pressure only open Low pressure only open In case a vehicle model has been selected from the data bank the various parameters are already indicated under their relevant icon otherwise the paramete...

Page 12: ...it checks if there is no pressure in the lines and starts the vaccum The vacuum cycle is automatically followed by a leak test cycle under vacuum according to the set parameters Note the unit gives ou...

Page 13: ...and DYE INJECTION it is possible to set the quantity of dye liquid to be injected into the A C system The procedure is similar to that used for the oil charging see aboveI Once set the parameters pres...

Page 14: ...R134a LOAD CELL TEST access to the display relevant to the various load cells test REPORT PRINT report printing on recovered refrigerant and oil quantity and injected by the unit 3 4 3 1 Self recycli...

Page 15: ...balance in order to test the weight measurement in order to calibrate the load cell follow the specific instructions in the service manual 3 4 3 4 Printing of refrigerant management report Press ENTE...

Page 16: ...ttings of the recovery in order the unit to carry out the utmost refrigerant recovery from the vehicle Note he setting of Max recovery mode may result in an increase of the recovery time Press ENTER B...

Page 17: ...of the opening time of the oil injection valve according to higher lower viscosity of oil to be injected and to the environment temperature This regulation is only necessary for models without oil sc...

Page 18: ...sable that the maintenance service be followed by an authorized centre in order to make sure that the maintenance operations are carried out in a correct way so that the warranty of the product is not...

Page 19: ...pump is a special waste and as such it has to be scrapped according to the regulations in force Warning switch off the unit and unplug from electrical socket before operating on the vacuum pump Elect...

Page 20: ...ribuita in accordo totale con i requisiti essenziali specificati dalle seguenti Direttive Comunitarie riguardanti la sicurezza dei macchinari la sicurezza delle apparecchiature in bassa tensione e la...

Reviews: