In spite of the earthing terminal, the swimming pool pumps must have its
equipotentiality terminal connected to the equipotentiality terminal in electric
wiring before it is put into use, the equipotentiality terminal is marked with the
symbol below. If you have any doubt please contact with your electric specialist.
Installation
Only qualified, licensed personnel should install pump and wiring whilst
observing local safety regulations.
The pump should be installed on the filter tank cover as instructed in manual
of Filtration Set.
The pump must be located away from corrosive or flammable chemicals and
least 10 feet (with filtration sets) away from the pool
Caution:
The pump must be located in Zone 2(usually at least 2 meters away from the
pool) and the power supply connection for the pump must be located in Zone
3(usually at least 3,5m away from the pool) according to the requirement stated
in International standard: Electrical installations of buildings – part 7:
Requirement for special installations or locations - Swimming pools and other
basins (IEC60364-7-702)
Position the unit away from the pool so that the filter pump is not directly
exposed to splashed water and rain.
Allow adequate access for servicing pump and hose connection and make
sure the rating label is visible after installation.
CAUTION:
Filtration Set should not be used without a permanently installed
wall skimmer or floating surface skimmer that can capture the larger debris
like leaves, twigs and branches, etc, that would totally block the pump. The
pump is easily damaged by such large debris and the guarantee does not
cover such damage.
ELECTRICAL WARNING!
Ground motor before connecting to electrical power
supply. Failure to ground motor can cause severe or fatal electrical shock
hazard. Do not ground to a gas supply line.
The user shall inspect and make sure about the effectiveness of protective
earthing of the building installation. In such case, an authorized qualified person
shall inspect the building installation.
To avoid dangerous or fatal electrical shock, turn OFF power to motor
before working on electrical connections.
Residual Current Device (RCD) tripping indicates an electrical problem. If
RCD trips and will not reset have a qualified electrician inspect and repair
electrical system.
The pump is to be supplied through a residual current device (RCD) having
a rated residual operating current not exceeding 30mA.
Exactly match supply voltage to motor nameplate voltage. Incorrect voltage
can cause fire or seriously damage motor and voids warranty. If in doubt
consult a licensed electrician.
The electrical installation should comply with the national wiring rules.
If the supply cord is damaged, it must be replaced by the manufacturer, its
service agent or similarly qualified persons in order to avoid a hazard.