Page 17
Each MIMIC module copies exactly one LED module. It is possible to
connect a further LED module to the MIMIC module or to copy the
primary LED module by using the open collector outputs of the MIMIC
modules.
The MIMIC Module just shows status information of the channels.
The buttons of the LED Module are deactivated.
2.2.
Redundancy of WinPro / MX62
The redundant structure of the system WinPro
®
/ MX62 means that the complete
safety functions are provided twice. From conversion of analog signals into bus
signals to evaluation in the CM and relay connection, any single error will not
lead to failure of the safety functions.
In addition, the two controllers of the CM continuously compare with each
other. Thus, not only single-error-protection is achieved but also maximum
availability.
To fulfill maximum safety criteria, the whole safety chain from detector to relay
must be provided twice. Linking of detectors and relays can be carried out with
the software
ConfigPro
.
2.3.
Control Pane of WinPro / MX62
The control panel consists of at least one LED module indicating 16 channels
and one logo module displaying the four LEDs for status monitoring.
Three further LED modules can increase the number of channels to 64. The
LED modules are identified by letters of A to D. The channels are always
numbered consecutively from 1 to 16.
Inputs
LED Module
Channel Identification
from
to
from
to
1
16
A
A 1
A 16
17
32
B
B 1
B 16
33
48
C
C 1
C 16
49
64
D
D 1
D 16
The inputs can also be freely allocated to the LED modules with the software
ConfigPro
.
Using the optional LCD module, the four system LEDs are place on the LCD
module. The logo module is not used.
Summary of Contents for MX62
Page 2: ...Subject to change without notice FE BA WinPro MX 62 R6 GB 1604CBR...
Page 4: ...Page 4...
Page 10: ...Page 10...
Page 18: ...Page 18...
Page 58: ...Page 58...
Page 60: ...Page 60...
Page 64: ...Page 64...
Page 65: ...Page 65 12 EU declaration of conformity...
Page 66: ...Page 66...
Page 68: ...Page 68...