94MS20 Rev. B4
4-3
AL56-480 Ballast Wiring
COM
277
CAP
277
CAP
COM
BALLAST
#1
L1
L2
T1
T2
RED
BLK
TERMINAL STRIP
CAP
277
COM
COM
277
CAP
29 (VIOLET).
NO. 20 (ORANGE
TO CAP. PACK).
AC IN
6 GA.
(BLK)
(BLK)
(RED)
16
18
17
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
(RED)
BALLAST
#2
BALLAST
#4
BALLAST
#3
CONTACTOR
AL54 / AL55 Ballast / Tap Switch Wiring
COM
208
240
CAP
240
CAP
208
COM
BALLAST
#1
BALLAST
#2
L1
ORANGE TO
CAP. PACK
L2
T1
T2
RED
BLK
CAP
240
208
COM
BALLAST
#4
COM
208
240
CAP
BALLAST
#3
1
2
3
4
5
6
10
11
12
VOLTAGE SELECTOR SWITCH
YELLOW TO
AUTOFORMER
RED TO FUSE
AUTOFORMER
240 VOLT
AC IN
10 GA.
16
18
17
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
TERMINAL STRIP
CONTACTOR