background image

10

10

FINAL COMMISSIONING

NOTICE

WARNING

As a safety critical component, buffers should not be installed without a switch.

1

  Ensure oil level is correct.

2

  Ensure striker is vertically aligned to +0.5 mm.

Complete electrical connections to the limit switch.

4

  Compress the buffer at slow speed across the full working stroke then allow to recoil.

5

  Allow the oil to settle for 30 minutes then recheck oil level – see 

Section 9

.

Finally, impact the buffer at the full rated speed of the elevator.

Complete final checks of oil level and the buffer is at correct working height.

Oleo recommends the final 7 step process is followed prior to commissioning:

CHECK: The maximum overall height against table below MLB 13-25 +0/-8.8mm and 
MLB 32 +0/-8.2mm of the figure stated.

NOTICE

If the buffer has not returned to the fully extended position (determined by measuring 
overall height) contact Oleo International.

MLB 13

0.4103

16.154

MLB 16

0.5323

20.957

MLB 18

0.6343

24.972

MLB 20

0.7823
30.799

MLB 25

1.1643

45.839

MLB 32

1.7305

68.130

m
in

Buffer Model

Extended Height

Summary of Contents for MLB 13

Page 1: ...INSTALLATION GUIDE ENGLISH MLB SERIES INSTALLATION GUIDE ELEVATOR BUFFERS MLB 13 32...

Page 2: ...itable for wet corrosive conditions The Oleo MLB elevator buffer is supplied containing compressed gas the plunger is held in the fully compressed condition during transportation by means of a bolt th...

Page 3: ...our regional health and safety laws are adhered to DO NOT lift buffer with the striker shown in Figure 1 Avoid contact as this may cause damage Always confirm the weight of the buffer to be lifted and...

Page 4: ...11 15 24 58 12 39 27 32 MLB 18 12 67 27 93 14 01 30 89 MLB 20 15 02 33 11 16 94 37 34 MLB 25 21 05 46 41 23 97 52 85 MLB 32 29 72 65 52 34 29 75 59 Kg Lbs Kg Lbs MLB 13 32 Range Buffer Model Without O...

Page 5: ...state now the buffer can be released by removing the transportation bolt The following is the recommended removal procedure For a controlled release lower the elevator car or equivalent onto the buffe...

Page 6: ...orage the plunger may require assistance to initially extend This should be done using rubber dead blow mallet to tap the underside of the buffer top plate GREEN in Figure 3 at 90 degree intervals unt...

Page 7: ...N MINIMUM MAXIMUM Take care when handling the oils Observe the oil manufacturers recommendations The oil level needs to be between the Minimum and Maximum marks indicated on the dipstick as shown in F...

Page 8: ...3 Gradually fill the buffer with oil until the oil level is visible between the minimum and maximum levels on the dipstick indicated on Figure 4 4 Allow the buffer to stand for a minimum of 30 minutes...

Page 9: ...e dipstick and inspect level The oil level needs to be between the maximum and minimum marks indicated on the dipstick as shown in Figure 4 5 Once oil level is correct replace dipstick and securely fa...

Page 10: ...ally impact the buffer at the full rated speed of the elevator 7 Complete final checks of oil level and the buffer is at correct working height Oleo recommends the final 7 step process is followed pri...

Page 11: ...d switch 2 Check the oil level is correct 3 Compress the buffer across its full working stroke 4 After the compression ensure the buffer has returned to its correct working height and visually check f...

Page 12: ...s Brigam Limited T A Savery and Co Limited is a company incorporated in England and Wales under company number 00272170 and whose registered office is at Grovelands Longford Road Exhall Coventry CV7 9...