DH3 WIRELESS GATEWAY
USER GUIDE
32.
MAPPING AN IMPORT TO AN OUTPUT ON
BASE UNIT
With the DH3, any import point can be mapped to an available output in
the same network whether it be to a Base Unit, Wireless Multi-I/O Module,
or another device with an output.
An import point can also be a function created by a Modbus Write function
so that the point can be written by a third-party Master device such a RTU
or PLC.
1.
Create a Modbus Write function
see sec. 30
2.
Share import point from DH3 to Base Unit using peer-to-peer
feature
see sec. 31
3.
Double-click on a Base Unit in project tree
4.
Right-click on a desired import point and select “copy”
5.
Click on Outputs tab
6.
Right-click over desired output target and select paste output
source
7.
Save project file and update both Gateways for changes to take into
effect