8. PROBLEMS, POSSIBLE CAUSES AND SOLUTIONS  

 

Caution! These operations must be carried out by specialized personnel. 
Before performing any service operation, be sure that the unit is disconnected from the elctric power supply. 
 

PROBLEM 

POSSIBLE CAUSE 

SOLUTION 

The electropump does not 
pump  water.  The  motor 
does not  run. 
 

- No power. 
- Motor protection tripped. 
- Demaged capacitator. 
- Shaft blocked. 
-  A  solid  object  is  blocking  the 
impeller. 

- Check the voltage. 
-  Verify  the  cause  and reset  the  switch. 
If  the  thermal  circuit  breaker  has 
tripped  wait  for  the  system  to  cool 
down. 
- Replace the capacitator. 
-  Verify  the  cause  and  unblock  the 
electropump. 
-  Disassemble  the  hydraulic  part  and 
verify if the impellers rotate freely. 
 

The  motor  runs  but  the 
electropump  does  not 
pump water. 
 

- The pump is sucking air. 
-  The  pump  rotates  in  the  wrong 
direction (Three-phase pumps). 
- Suction grid blocked. 
- Check valve blocked. 
- Low voltage. 
 

- Make sure that the joints are air-tight. 
Check  that  the  liquid  has  not  dropped 
below the minimum level. 
- Invert the electric phase connection of 
rotation. 
- Clean the suction grid. 
- Clean or replace valve. 
- Use electric cables of larger diameter. 

The  electropump  stops 
after  running  for  a  short 
period  of  time  because 
one  of  the  termal  motor 
circuit breaker trips. 
 

-  The  power  supply  does  not 
correspond  with  the  data  on  the 
nameplate. 
- The pump has run without liquid. 
 

- Check the voltage on the power supply 
cables leads. 
-  If  the  pump  is  equipped  with  a  float 
switch,  verify  if  this  is  functioning 
working  it  manualy.  Reestablish  the 
water level before restart the pump. 

If in spite of carring out the above operations the problem still persists contact the nearest service centre. 
 

 

Summary of Contents for AQUARAIN RJ 5.60.3

Page 1: ...NL DE AQUARAIN FR IT ES EN PT OLIJU INSTRUCTIONS Installation and operation instructions The realiability is our brand...

Page 2: ...vertically 4 1 PUMP INSTALLATION IN THE RESTING POSITION TANKS The pump can be installed on the flat botton surface of a tank with a fix or raising strainer fig 1 1 fig 1 2 so that abrasive matter is...

Page 3: ...otector with its respective electrodes to prevent the pump against dry runnig frequency protetor against phase lack Thermal protector gauged for the motor mains voltage 6 STARTING Never run the pump d...

Page 4: ...ctropump does not pump water The pump is sucking air The pump rotates in the wrong direction Three phase pumps Suction grid blocked Check valve blocked Low voltage Make sure that the joints are air ti...

Page 5: ...obomba Instale a bomba apenas verticalmente 4 1 INSTALA O DA BOMBA EM REPOUSO TANQUES A bomba pode ser instalada na superf cie plana de um tanque com um filtro fixo ou flutuante fig 1 1 fig 1 2 de mod...

Page 6: ...a protec o contra a falta de gua um rel de frequ ncia contra a falta de fase um rel t rmico calibrado para a corrente do motor 6 ARRANQUE Nunca ligar a bomba em seco nem mesmo por um curto per odo de...

Page 7: ...lsores giram livremente O motor arranca mas a electrobomba n o fornece gua A electrobomba absorve ar Sentido de rota o errado trif sica Filtro de aspira o obstru do V lvula de reten o bloqueada Tens o...

Page 8: ...lectrico para suspender la electrobomba Evitar el funcionamiento en seco Instale la bomba s lo verticalmente 4 1 INSTALACION DE LA ELECTROBOMBA Tanque La bomba puede instalarse en la superficie plana...

Page 9: ...a la falta de fase un rel t rmico calibrado para la corriente del motor 6 ARRANQUE Nunca se debe realizar en seco Al menos se debera sumergir a una profundidad de 200mm No se debe retirar la electrobo...

Page 10: ...a su enfriamento Substituir condensador Desbloquear parte hidraulica y comprobar que giran libremente El motor funciona pero la electro bomba no saca agua Mal sentido de giro Filtro aspiracion obstrui...

Page 11: ...ou inflammables Cette pompe est pr vue pour tre utilis e de mani re fixe D brancher la pompe chaque fois qu elle doit tre transport e 4 INSTALLATION Ne pas utiliser le c ble pour placer ou suspendre l...

Page 12: ...dissement Une protection a rienne suppl mentaire est conseill e 5 4 AquaRain 400V Les pompes triphas es devront tre raccord es au r seau lectrique par l interm diaire d un coffret il comportera Une pr...

Page 13: ...eur tourne mais la pompe ne d livre pas d eau La pompe aspire de l air La pompe tourne dans le mauvais sens Triphas La cr pine est colmat e Le clapet est bloqu Tension trop basse Assurez vous qu il n...

Page 14: ...secco dell elettropompa Installare la pompa solo verticalmente 4 1 INSTALLAZIONE POMPA NELLA POSIZIONE DI RIPOSO SERBATOI La pompa pu essere installata sulla superficie piana di un serbatoio con un fi...

Page 15: ...con Dispositivo elettronico che comanda le sonde per un perfetto controllo di livello dell acqua evitando il funzionamento a secco de1la pompa Protettore termico con la giusta taratura amperometrica...

Page 16: ...pomba non pompa acqua La pompa sta aspirando aria La pompa ruota nella direzione sbagliata pompe trifasi Griglia di aspirazione ostruita Valvola di controllo bloccata Bassa tensione Accertarsi che le...

Page 17: ...en Pomp moet ondergedompeld blijven droogloop altijd vermijden Pomp enkel vertikaal plaatsen 4 1 Installatie op bodem watertanken De pomp kan op de bodem van de tank geplaatst worden Plaats een zuigko...

Page 18: ...ek beveiliging Een aangepaste thermische beveiliging met snelle uitschakeling 6 OPSTARTEN Nooit de pomp zonder water laten draaien zelfs niet voor een korte periode De pomp niet laten starten met een...

Page 19: ...en dat de waaiers losdraaien De motor draait maar de pomp geeft geen water De pomp zuigt lucht De pomp draait in de verkeerde richting Driefasig De korf is dicht De terugslagklep zit vast Te lage span...

Page 20: ...al aus wenn Sie die Pumpe transportieren 4 INSTALLATION Verwenden Sie niemals das Stromkabel um die Pumpe in den Brunnen abzulassen Vermeiden Sie Trockenlauf Trockenlauf f hrt zur Zerst rung der Pumpe...

Page 21: ...ssen mit einer Pumpensteuerung und Motorschutz ber und Unterlast und Phasenausfallschutz betrieben werden Trockenlaufschutz mit Elektroden oder ber Motorstrommessung wird empfohlen 6 BEGINN Niemals di...

Page 22: ...saugt Luft Die Pumpe dreht sich in die falsche Richtung Drehstrom Pumpen Ansauggitter blockiert R ckschlagventil blockiert Spannung zu niedrig Stellen Sie sicher dass die Abdichtungen luftdicht sind...

Page 23: ...23...

Page 24: ...e d claration sont conformes la directive 2006 42 CE EN ISO 12100 EN 60335 1 EN 60335 2 41 2004 108 CE DICHIARAZIONE DI CONFORMITA I prodotti su elencati sono conformi alle direttiva 2006 42 CE EN ISO...

Reviews: