background image

14

960

630

850

135

130

9,5

0,64

73,5

260

270

9,68

>10

<20

2

2,92

2,92

60

400x320x270

32

3

TROUBLESHOOTING

In case of malfunctioning, check the following table.
If, after the checks and controls suggested, the problem persists, contact the authorised technical service.

DEFECT
• The glass on the firebox door is

covered with soot or the firebox
chamber is dirty with black smoke.

• Irregular air draught

• Exhaust outside with too much black

smoke.

• Smoke coming out of the appliance

CAUSE
• Draught too low < 10 Pa

• Incorrect adjustments.

• Too much fuel introduced.
• Firewood with too much relative humidity.

• Unsuitable fuel.

• Unsuitable or dirty flue

• Appliance dirty inside

• Appliance lit with green wood

• Smoke outlet partially blocked.

• The door on the firebox is open while the

fire is alight.

• Insufficient draught.

• Incorrect adjustment when lighting.

• The appliance needs to be cleaned

REMEDY
• Check that the smoke outlet pipe duct

is not blocked.

• Modify the flue: chimney too high or

terminal hood not suitable, or improve
insulation.

• Check the indications in the

"Adjustments" and "Fuel to be used"
chapters.

• Reduce the quantity.
• Dry the damp wood before using.
• Check the indications in the "Fuel"

paragraph

• Call in a chimney sweep

• Clean

• Use better quality seasoned

firewood.

• Call in a qualified technician.

• Close the door.

• Call in a qualified technician for an

inspection.

• Check the indications in the

"Adjustments" and "Fuel to be used"
chapters.

• Clean the appliance and connection

tubes to the chimney flue.

Width (with handrail)

Depth (with handrail)

Height

Weight of complete appliance

Diameter of smoke exhaust

Total nominal power

CO emissions (with13% of oxygen)

Efficiency

Average smoke temperature

Smoke temperature

Mass flow of smoke

Minimum draught to chimney

Maximum draught to chimney

Recommended fuel; pieces of beech firewood

Nominal fuel load

Hourly consumption

Refuelling interval

Dimensions H x L x D

Oven Volume

TECHNICAL CHARACTERISTICS

m m

m m

m m

k g

m m

kW

%

%

°C

°C

g/sec

Pa

Pa

k g

kg/h

minuti

m m

lt

Summary of Contents for Arcadia PANORAMICA

Page 1: ...INSTRUCTIONS FOR INSTALLATION USE AND MAINTENANCE GB...

Page 2: ...ONFIREWOOD 2 4 STARTINGUP 2 5 LOADINGTHEFUEL 2 6 LIGHTINGANDUSE 2 7 LIGHTINGUP 2 8 LOADINGANDRE LIGHTINGWITHEMBERS 2 9 SHAKINGTHEFIREBOXGRATE 2 10 ASH BOX 2 11 FOOD WARMING BOX 2 12 FIREWOODBOX 2 13 P...

Page 3: ...n force PRELIMINARY OPERATIONS Carefully remove the packing The packing material must be recycled by disposing in the special containers or in the local municipal waste disposal site Before installati...

Page 4: ...ing appliances in this case wood fired cookers by law must have a chimney flue built in compliance with regulations on force for the evacuation of exhaust fumes The points described below are norms of...

Page 5: ...re of the front part pressing it downwards MOUNTING THE SMOKE DISCHARGE COLLAR Take the smoke discharge collar fig 4 ref A located in the oven compartment and rest it on the relative seat on the plate...

Page 6: ...n the appliance being used and the chimney flue must receive exhaust fumes from one heat source only An appliance can consist of a fireplace and cooking oven with a single exhaust point to the chimney...

Page 7: ...ned that they cannot be obstructed The airflow can also be obtained from an adjacent room to that of the installation as long as this flow happens freely through permanent outlets communicating with t...

Page 8: ...is corrected Do not block the openings or aspiration and heat dispersion slats All repairs or replacements of worn components must only be carried out by a qualified service centre Only use original...

Page 9: ...mic glass so you can see the flame and the food being cooked inside the oven The basic versions have the smoke outlet on the right while in left hand versions have the positions of the firebox and the...

Page 10: ...completely alight Return the primary air control to the normal use position as indicated in the ADJUSTMENTS chapter SHAKINGTHEFIREBOXGRATE Insert the end of the poker in the hole on the grate shaker...

Page 11: ...OVEN The cooker is equipped with an oven in enamelled steel for cooking food The oven has internal glass and a thermometer to simplify temperature checks The temperature shown by the thermometer is in...

Page 12: ...e presence of hot ash clean the holes slots in the base of the grate Cleaning the outside This must be done with the appliance cold Steel cast iron parts use a cloth soaked in a substance suited for t...

Page 13: ...m the following operations Cleaning of the exhaust gas ducts Check the gaskets and replace if necessary Check the flue It is advisable to arrange an annual maintenance contract with an OLIMPIA SPLENDI...

Page 14: ...ke outlet pipe duct is not blocked Modify the flue chimney too high or terminal hood not suitable or improve insulation Check the indications in the Adjustments and Fuel to be used chapters Reduce the...

Page 15: ...15...

Page 16: ...16...

Reviews: