RULES AND REGULATIONS

· Read this manual carefully as it contains important indications and instructions concerning the installation, use, maintenance and

safety of the product.

· This appliance must only be installed and used in a room deemed suitable by the specific authorities and in compliance with the

relevant rules and regulations.

· The technological systems and the installation of the appliance must be done by professional qualified personnel authorised to

release the certificate of conformity and compliance with the regulation in force.

· All the laws, rules and regulations in force concerning civil and industrial buildings must be respected, always using PPE and other

means foreseen by law.

· All laws, rules and regulations concerning the systems, chimney flues, electricity, water, ventilation and aspiration must be respected.
· The manufacturer declines all responsibility arising from incorrect installation, tampering, incorrect use of the

appliance, improper use, poor maintenance, and failure to respect regulations in force.

PRELIMINARY OPERATIONS

· Carefully remove the packing.
· The packing material must be recycled by disposing in the special containers or in the local municipal waste disposal site.
· Before installation, make sure that the appliance is intact, in case of doubt, do not use it and contact the vendor.

POSITIONING THE APPLIANCE

· The place where the appliance is installed must have:

- A floor suitable for supporting a weight greater than that of the appliance. If the existing building is not suitable, appropriate

measures must be taken (e.g. a load distribution plate);

 - Flooring suitable for heat dispersion which protects the building against fire risks;
 - The installation of the appliance must guarantee easy access for its cleaning, the cleaning of the exhaust gas ducts and the

chimney flue;

- The appliance must be positioned on a horizontal surface;
- A minimum distance from adjacent inflammable material;
- A permanently ventilated room in accordance with the regulations in force.

PROTECTION OF THE FLOOR

· The appliance must rest on a refractory surface. In the case of inflammable flooring (wood, carpet, etc.) prearrange a refractory base

(steel sheet, tiles or similar) with the following size:
- Frontal protrusion 

≥≥

≥≥

 500 mm;

- Side protrusion 

≥≥

≥≥

 300 mm;

- Rear protrusion 

≥≥

≥≥

 100 mm.

1

1.1

1.2

1.3

1.4

1

Summary of Contents for Arcadia PANORAMICA

Page 1: ...INSTRUCTIONS FOR INSTALLATION USE AND MAINTENANCE GB...

Page 2: ...ONFIREWOOD 2 4 STARTINGUP 2 5 LOADINGTHEFUEL 2 6 LIGHTINGANDUSE 2 7 LIGHTINGUP 2 8 LOADINGANDRE LIGHTINGWITHEMBERS 2 9 SHAKINGTHEFIREBOXGRATE 2 10 ASH BOX 2 11 FOOD WARMING BOX 2 12 FIREWOODBOX 2 13 P...

Page 3: ...n force PRELIMINARY OPERATIONS Carefully remove the packing The packing material must be recycled by disposing in the special containers or in the local municipal waste disposal site Before installati...

Page 4: ...ing appliances in this case wood fired cookers by law must have a chimney flue built in compliance with regulations on force for the evacuation of exhaust fumes The points described below are norms of...

Page 5: ...re of the front part pressing it downwards MOUNTING THE SMOKE DISCHARGE COLLAR Take the smoke discharge collar fig 4 ref A located in the oven compartment and rest it on the relative seat on the plate...

Page 6: ...n the appliance being used and the chimney flue must receive exhaust fumes from one heat source only An appliance can consist of a fireplace and cooking oven with a single exhaust point to the chimney...

Page 7: ...ned that they cannot be obstructed The airflow can also be obtained from an adjacent room to that of the installation as long as this flow happens freely through permanent outlets communicating with t...

Page 8: ...is corrected Do not block the openings or aspiration and heat dispersion slats All repairs or replacements of worn components must only be carried out by a qualified service centre Only use original...

Page 9: ...mic glass so you can see the flame and the food being cooked inside the oven The basic versions have the smoke outlet on the right while in left hand versions have the positions of the firebox and the...

Page 10: ...completely alight Return the primary air control to the normal use position as indicated in the ADJUSTMENTS chapter SHAKINGTHEFIREBOXGRATE Insert the end of the poker in the hole on the grate shaker...

Page 11: ...OVEN The cooker is equipped with an oven in enamelled steel for cooking food The oven has internal glass and a thermometer to simplify temperature checks The temperature shown by the thermometer is in...

Page 12: ...e presence of hot ash clean the holes slots in the base of the grate Cleaning the outside This must be done with the appliance cold Steel cast iron parts use a cloth soaked in a substance suited for t...

Page 13: ...m the following operations Cleaning of the exhaust gas ducts Check the gaskets and replace if necessary Check the flue It is advisable to arrange an annual maintenance contract with an OLIMPIA SPLENDI...

Page 14: ...ke outlet pipe duct is not blocked Modify the flue chimney too high or terminal hood not suitable or improve insulation Check the indications in the Adjustments and Fuel to be used chapters Reduce the...

Page 15: ...15...

Page 16: ...16...

Reviews: