background image

S

S

S

e

e

e

r

r

r

v

v

v

i

i

i

c

c

c

e

e

e

 

 

 

M

M

M

a

a

a

n

n

n

u

u

u

a

a

a

l

l

l

 

 

 

 
 
 
 
 
 
 
 

 

SECCO PIÙ - SECCO SUPER 

 

 

 
Display: 
 
Usually the display shows set point, press “Hr”  button to see room humidity. Set point can be regulated 
between  30  and  90,  5  by  5,  pressing  UP  or  DOWN.  (only  for  Secco  Super)To  select  minimum  or 
maximum fan speed, press the fan button. 
 
Stand by mode: 
 
To  start  and  stop  the  unit  pres  Stand  By  button.  In  stand  by  mode  every  component  is  off,  there  is  no 
measuring and no programming is possible. 
 
Dry mode: 
 
Compressor and fan start if the difference between room humidity and set point is higher than 3 and if a 
time  higher  than  “Cf”  has  passed  after  last  stop.  Compressor  and  fan  keep  going  until  the  difference 
between  room  humidity  and  set  point  is  higher  than  -3.  When  compressor  stops  the  fan  keep  going  for 
another 30 seconds. When the tank is full all components turn off, tank led turns on and the unit buzzes for 
15 sec. Pressing one button during the 15 sec the buzz stops.  
All inputs are saved in an eeprom, after a power failure the unit will restart considering last inputs. 
 
Defrosting mode: 
 
When  there  is  ice  on  the  evaporator  (evaporator  temperature  <  “Ft”  and  compressor  on)  the  compressor 
keep  working  for  another  30  min,  than  it  stops  while  the  fan  keep  going  until  evaporator  temperature  > 

Reviews: