10
After accessing the “Fast hot water” function, you can
choose whether or not to activate - along with the
unit compressor - the electric heater inserted in the
water tank for the production of domestic hot water.
To activate the function, click directly on the word
“On” and then con
fi
rm with “OK”.
Fast hot water
On
OK
Cancel
NOTES:
1.
If the water tank for this model is not installed (and correctly set), this function will not be available.
2.
To ensure even better energy saving, it is advisable to disable this function.
3.
If the relative function is activated (paragraph 8.3), the value of this parameter will be stored in the
memory and automatically reset after any possible voltage failure.
4.
The default value for this parameter is: “O
ff
“.
4.3.
Activating the function for fast domestic hot water production (Fast hot water)
After accessing the “Cool+hot water” function, you
can select “Cool” to force the unit to
fi
rst of all satisfy
the system terminal side; by selecting “Hot water”, pri-
ority is given to domestic hot water production. Select
the priority, then press “OK” to con
fi
rm.
Cool + hot water
Hot water
Cool
OK
Cancel
NOTES:
1.
If the water tank for this model is not installed (and correctly set), this function will not be available.
2.
If the relative function is activated (paragraph 8.3), the value of this parameter will be stored in the
memory and automatically reset after any possible voltage failure.
3.
The default value for this parameter is: “Cool”.
4.4.
Setting the priority between cooling and domestic hot water production (Cool+hot water)
11
After accessing the “Heat+hot water” function, you
can select “Heat” to force the unit to
fi
rst of all satisfy
the system terminal side; by selecting “Hot water”, pri-
ority is given to domestic hot water production. Select
the priority, then press “OK” to con
fi
rm.
Heat + hot water
Hot water
Heat
OK
Cancel
NOTES:
1.
If the water tank for this model is not installed (and correctly set), this function will not be available.
2.
If the relative function is activated (paragraph 8.3), the value of this parameter will be stored in the
memory and automatically reset after any possible voltage failure.
3.
The default value for this parameter is: “Heat”.
4.5.
Set the priority between heating and domestic hot water production (Heat+hot water)
After accessing the “Quiet mode” function by clicking
on the label, you can change the value to be assigned
to the function. The possible values are:
t
“On” = Function active
t
“O
ff
” = Function not active
t
“Clock timer” = Function active but in accord-
ance with the time settings provided
If you select “Clock timer”, two keys will appear. Use
them to set the start and end of the “Quiet mode” acti-
vation period. To set the values, press the time label in
question and set the hours and minutes by sliding the
value up or down with your
fi
ngertip (the value high-
lighted in blue in the middle of the selection window),
as shown in the
fi
gure:
00 00
01 01
02 02
23 59
22 58
Quiet mode
Quiet mode: Timer
Start Timer: 00:00
End Timer: 00:00
NOTES:
1.
Every time you press on the label, the value will change. Once you have selected the required value,
press the icon to save and implement the setting.
2.
The function can still be set if the unit is O
ff
, but it will only be implemented if the unit is activated.
3.
When the function is set to “On”, it will automatically be set to “O
ff
” if the unit is switched o
ff
manu-
ally, whereas the setting will remain valid until the end of the selected period if the function value is
set to “Clock timer”.
4.
If the relative function is activated (paragraph 8.3), the value of this parameter will be stored in the
memory and automatically reset after any possible voltage failure.
5.
The default value for this parameter is: “O
ff
”.
00 00
01 01
02 02
23 59
22 58
Quiet mode
Quiet mode: Timer
Start Timer: 00:00
End Timer: 00:00
4.6.
Setting the noise reduction function (Quiet mode)