38
Label Error
Description
Code
Comp. stalling
Indicates that the compressor is currently stalled
LE
Overtemp. mod.
Indicates that an overtemperature has been detected on a component
(heatsink, IPM or PFC)
P8
T mod. sensor
Indicates that an error has been detected on the temperature sensor for a
component (heatsink, IPM or PFC)
P7
Charge circuit
Indicates an error on the charging circuit
Pu
AC voltage
Indicates a power supply error
PP
Temp driver
Indicates an error a
ff
ecting the external air sensor
PF
AC contactor
Indicates a protection status on the power supply
P9
Temp. drift
Indicates a protection status for drift temperature
PE
Sensor con.
Indicates a protection status for the sensor monitoring the phases
Pd
ODU Com.
Indicates a serial communication error between the display and the out-
door unit
E6
Temp RGL
Indicates an error a
ff
ecting the temperature sensor on the cooling circuit
gas line
F0
Temp RLL
Indicates an error a
ff
ecting the temperature sensor on the cooling circuit
fl
uid line
F1
Summary of Contents for SHERPA MONOBLOC
Page 191: ......
Page 192: ...262617B...