background image

G1/2

1

2

Installation Instructions

Rome Dual Shower (chrome)

Installation Instructions

1. ½”BSP Male Thread  
2. ½”BSP Connector 
3. Mains Inlet Wall Post 
4. Bottom Rail Post 
5. Hand Piece Holder
6. Sliding Rail Tube

7. Shower Arm
8. Shower Head
9. Shower Hose
10. Hand Piece
11.Wall Bracket

1

2

3

6

650±10mm

3

6

5

9

10

7

8

4

11

4

5

Please ensure that the lines are flushed prior to installation as contaminates in the water can damage the flow 

General Note

:This product is to be installed by a licensed plumber, installation must comply with AS/NZS 3500 

and local plumbing codes.

Pressures & Temperatures

Maximum Hydrostatic Pressure - 500 kpa. (Asper AS/NZS3500)

Note: AS/NZS 3500.1-2003 (Clause 3.3.4) states that “Provision shall be made to ensure that the maximum static 

Note: Pressures above 500kPa can cause damage from water hammer, reduced life of appliances, taps and fittings, 
and cause excessive noise in the system.

Minimum Hydrostatic Pressure - 100 kpa
The Maximum operating temperature for the Shower is 65°C.

pressure at any outlet, other than a fire service outlet, within abuilding does not exceed 500 kPa. 

regulator and also affect the performance of the Shower.

To the consumer

1. The Shower is to only be cleaned with warm soapy water

2. 

Under No Circumstances

 should any abrasive, cream or acid based cleaning agents be used as these types of cleaners

will damage the finish, shower head nipples and seals.

1. Remove product from packaging and check for damages, if the product is damaged do not install and return to the store of 
    purchase.
2. The WELS compliant flow regulator has been pre-assembled in the shower head and hand piece inlet, to comply with WELS 
    the flow regulators must remain in place.
3. From the centre of the ½” BSP male thread measure a level vertical line 650mm down from centre of ½” BSP and mark position.
4. Apply thread seal tape to the 1/2” BSP male thread (1).
5. Screw ½” BSP connector (2) to ½” BSP male thread (1) and tighten.
6. Loosen wall support bracket (4) and remove wall bracket (11).
7. Drill hole at pre-marked 650mm position to fix the wall bracket (10) to the wall, use the wall plug and screw supplied or a 
    suitable wall plug and screw for the wall material.
8. Screw wall bracket (11) into position.
9. Screw the sliding rail tube (6) onto the mains inlet wall post (3) ensure sealing washer is in place.
10. Feed the hand piece holder (5) onto the shower rail (6).
11. Slid the bottom rail post (4) onto the rail (6).
12. Tighten the wall support bracket (4) to the shower rail (6).
13. Slide the mains inlet wall post (3) onto the ½” BSP connector (2).
14. Align the bottom rail post (4) to the wall bracket (11).
15. Slide upper curved shower rail (6) onto main inlet wall post (3) and tighten grub screw.
16. Firmly push the shower and rail on the  ½” BSP connector (2) and wall bracket (11).
17. Tighten both fittings with allen key supplied.
18. Screw shower hose (9) to the bottom of the shower rail (6) ensuring sealing washer is in place.
19. Screw hand piece (10) to shower hose (9) ensuring flow regulator is in the hand piece and sealing washer is in the hose.
20. Screw shower head (8) to shower arm (7) ensuring flow regulator and rubber seal is in the shower head.