d-Color MF4003/MF3303
I SERVICE MODE > 16. FAX
I-104
Items
Address
Data
Default
Bit
Contents
Setting
Data
For transmission
00130076
7-3 -
-
00000000
2
Restrict plural fax destination
0: OFF
1: ON
OFF
1
Destination check display function
0: OFF
1: ON
OFF
0
Screen display during transmission
0: OFF
1: ON
OFF
Lower limit setting of the signal
send-out level setting range
00130077
7-0 Lower limit setting of the signal send-out level setting
range (-dBm)
-15 dBm
00001111
Character-to-search default for
FAX main screen
00130078
7-0 00000000 00000000 00000000 00000001: [Favorite]
00000000 00000000 00000100 00000000: [ABC]
00000000 00000000 00001000 00000000: [DEF]
00000000 00000000 00010000 00000000: [GHI]
00000000 00000000 00100000 00000000: [JKL]
00000000 00000000 01000000 00000000: [MNO]
00000000 00000000 10000000 00000000: [PQRS]
00000000 00000001 00000000 00000000: [TUV]
00000000 00000010 00000000 00000000: [WXYZ]
00000000 00000100 00000000 00000000: [etc]
[Favorite]
00000001
00130079
00000000
0013007A
00000000
0013007B
00000000
Initial program display page
0013007D 7-0 00000001: 1 page to 00011011: 27 pages
00000000: Temporary distribution
1 page
00000001
Destination type display setting
00130080
7-0 0: Do not display
1: Display
Do not display
00000000
00130081
00000000
00130082
00000000
00130083
00000001
No. of destination display
characters setting
00130084
7-0 00001110: 14 characters
00011000: 24 characters
14 characters
00001110
Lower limit of receive time
interval setting
00980000
7-0 Lower limit of receive time interval setting (unit: sec.)
0 sec.
00000000
Upper limit of receive time
interval setting
00980001
7-0 Upper limit of receive time interval setting (unit: sec.)
45 sec.
00101101
16.12 Function parameter list (for separate line)
16.12.1 Function setting 1
Items
Address
Data
Default
Line 1
Line 2
Line 3
Line 4
Bit
Contents
Setting
Data
Transmission ATT
000E0090
000E01A0
000E02B0
000E03C0 7-4 Tone signal/FSK
transmission ATT (-dBm)
0000: 0 dBm to 1111: -15
dBm
-10 dBm
10101010
3-0 High-speed signal
transmission ATT (-dBm)
0000: 0 dBm to 1111: -15
dBm
-10 dBm
CED transmission
ATT
000E0091
000E01A1
000E02B1
000E03C1 7-4 -
-
00001010
3-0 CED/ANS transmission ATT
(-dBm)
0000: 0 dBm to 1111: -15
dBm
-10 dBm
CD/SED ON level
000E0092
000E01A2
000E02B2
000E03C2 7-2 -
-
00000011
1-0 CD/SED ON level
00: -33 dBm
01: -38 dBm
10: -43 dBm
11: -48 dBm
-48 dBm
Cable equalizer
000E0093
000E01A3
000E02B3
000E03C3 7-6 -
-
00000000
5-4 Cable EQL transmission
selection
00: OFF
01: Send only
10: Receive only
11: Send and receive
OFF
Service Manual
Y119930-3
Summary of Contents for d-Color MF 4003
Page 1: ...Multifunction Digital Copier d Color MF4003 MF3303 Service Manual Version 2 0 Code Y119930 3 ...
Page 48: ...This page is intentionally left blank ...
Page 54: ...This page is intentionally left blank ...
Page 70: ...This page is intentionally left blank ...
Page 76: ...This page is intentionally left blank ...
Page 98: ...This page is intentionally left blank ...
Page 216: ...This page is intentionally left blank ...
Page 354: ...This page is intentionally left blank ...
Page 388: ...This page is intentionally left blank ...
Page 398: ...This page is intentionally left blank ...
Page 570: ...This page is intentionally left blank ...
Page 572: ...This page is intentionally left blank ...
Page 574: ...This page is intentionally left blank ...