d-Color MF4003/MF3303
L TROUBLESHOOTING > 3. TROUBLE CODE
L-71
Trouble detection condition The file or data that is necessary to start the virus scan has been lost.
Trouble isolation
-
Relevant electrical parts
Storage board (STRGB)
Procedure
1.
Reboot the machine. (MFP will reboot maximum 2 times by itself.)
2.
3.19.5 CE101
Contents
Trouble type
CE101: Browser finish detected
Rank
C
Trouble detection condition
• The browser is automatically recovered (restarted) after the main body detected that the browser (separate
process) has stopped with fault.
• When the “Malfunction finish is detected over predetermined number of times” or “the browser task process is
except in idle (printing, etc.)”.
Trouble isolation
-
Relevant electrical parts
• CPU board (CPUB)
• Base board (BASEB)
Procedure
1.
Check the connectors on BASEB for proper connection and correct as necessary.
2.
3.
3.19.6 CE201
Contents
Trouble type
CE201: Transmission operation log storage fault
Rank
C
Trouble detection condition When the transmission log storage failed, it repeats retrial until transmission operation log is stored. The trouble is
detected when the retrial failed for predetermined number of times.
Trouble isolation
-
Relevant electrical parts
• CPU board (CPUB)
• Base board (BASEB)
Procedure
1.
Check the connectors on BASEB for proper connection and correct as necessary.
2.
3.
3.19.7 CE202
Contents
Trouble type
CE202: PDL interpreter error
Rank
C
Trouble detection condition An error inside the CPU board (CPUB) is detected during converting the PDL information.
Trouble isolation
-
Relevant electrical parts
• CPU board (CPUB)
• Base board (BASEB)
Procedure
1.
Turn OFF the main power switch and unplug the power cord. Connect the power cord after 15 sec. or more, and turn ON the main power
switch.
2.
Select [Service Mode] -> [State Confirmation] -> [Memory/Storage Adjustment] -> [Format] -> [Logical Format] and perform the function.
3.
Select [System 1] -> [Initialization] -> [Clear All Data] and perform the function.
4.
5.
3.19.8 CE203
Contents
Trouble type
CE203: Unrecoverable error
Rank
C
Trouble detection condition An error does not recover even after an auto recovery.
Trouble isolation
-
Relevant electrical parts
• CPU board (CPUB)
• Base board (BASEB)
Y119930-3
Service Manual
Summary of Contents for d-Color MF 4003
Page 1: ...Multifunction Digital Copier d Color MF4003 MF3303 Service Manual Version 2 0 Code Y119930 3 ...
Page 48: ...This page is intentionally left blank ...
Page 54: ...This page is intentionally left blank ...
Page 70: ...This page is intentionally left blank ...
Page 76: ...This page is intentionally left blank ...
Page 98: ...This page is intentionally left blank ...
Page 216: ...This page is intentionally left blank ...
Page 354: ...This page is intentionally left blank ...
Page 388: ...This page is intentionally left blank ...
Page 398: ...This page is intentionally left blank ...
Page 570: ...This page is intentionally left blank ...
Page 572: ...This page is intentionally left blank ...
Page 574: ...This page is intentionally left blank ...