d-Color MF4003/MF3303
L TROUBLESHOOTING > 8. CS Remote Analysis ERROR CODE
L-95
Error code
Contents
Solution
• Session ID inconsistent
8.2.4 3###
Error code
Contents
Solution
3002
http request result problem
• Unopened client ID was specified
Check the http server system settings.
• Authentication setting for address of the
destination where the server is connected
• Location indicated for a folder
• Connection ID
• Password
3003
http request result problem
• Receive time out occurred
3004
http request result problem
• Receive error occurred. Or wrong request URL was specified.
3005
http request result problem
• Content-Length or receive size exceeded the specified max.
transfer size. Message body size was too large.
3006
http request result problem
• Due to reset, process was stopped. Or message body size
exceeded the specified max. transfer size.
3007
http request result problem
• Internal error occurred. Or due to internal reset, process was
stopped.
3008
http request result problem
• Connection to WebDAV server failed.
3009
http request result problem
• Error occurred during transmission to the WebDAV server.
3010
http request result problem
• Time out occurred during transmission to the WebDAV server.
3011
http request result problem
• Connection to the proxy server failed.
3012
http request result problem
• The proxy server refused CONNECT request.
3013
http request result problem
• The proxy server was set to enabled, but the proxy server host
was not set.
3014
http request result problem
• Proxy server authentication failed.
3015
http request result problem
• Other errors were sent from the proxy server.
3016
http request result problem
• Internal error occurred.
3017
http request result problem
• As the device application specified MIO_REQBODY_ERROR,
process was stopped.
8.2.5 4###
Error code
Contents
How to correct
4103
After the main power switch is switched ON, HTTP communication is
attempted under the condition where HTTP communication is not
ready.
Wait for a while and try transmitting again.
4106
When data is uploaded from main body to the web server, the network
connection is not enabled and main body cannot start communication.
Wait for a while and try transmitting again.
41FA
Control error
• MIO response timed out.
Turn the main power switch OFF and then ON.
8.2.6 5###
Error code
Contents
Solution
5###
MIO detects error at file sending.
Check the http server environment.
8.2.7 6###
Error code
Contents
Solution
6###
MIO detects error during a sending sequence.
Check the http server environment.
8.2.8 7###
Error code
Contents
Solution
7000
Acquisition of the certificate used in product authentication from a USB
device or PSWC failed.
Acquire a new certificate (within 6 days after the
issue).
Y119930-3
Service Manual
Summary of Contents for d-Color MF 4003
Page 1: ...Multifunction Digital Copier d Color MF4003 MF3303 Service Manual Version 2 0 Code Y119930 3 ...
Page 48: ...This page is intentionally left blank ...
Page 54: ...This page is intentionally left blank ...
Page 70: ...This page is intentionally left blank ...
Page 76: ...This page is intentionally left blank ...
Page 98: ...This page is intentionally left blank ...
Page 216: ...This page is intentionally left blank ...
Page 354: ...This page is intentionally left blank ...
Page 388: ...This page is intentionally left blank ...
Page 398: ...This page is intentionally left blank ...
Page 570: ...This page is intentionally left blank ...
Page 572: ...This page is intentionally left blank ...
Page 574: ...This page is intentionally left blank ...