3.9.6 C3922, C3925, C3926
Contents
Trouble type
• C3922: Fusing sensor wire breaks detection (Edge of the heating roller)
• C3925: Fusing sensor wire breaks detection (Main of the heating roller)
• C3926: Fusing sensor wire breaks detection (Center of the heating roller)
Rank
A
Trouble detection condition
• C3922: The maximum value and minimum value of detected temperature of the heating roller thermistor/Edg
(TH1) is compared after a lapse of given time from starting of warm up and the gap between the value of
maximum and minimum is below or above given temperatures.
• C3925: The maximum value and minimum value of detected temperature of the heating roller temperature
sensor (TEMS2) is compared after a lapse of given time from starting of warm up and the gap between the
value of maximum and minimum is below or above given temperatures.
• C3926: The maximum value and minimum value of detected temperature of the heating roller thermistor/Ctr
(TH2) is compared after a lapse of given time from starting of warm up and the gap between the value of
maximum and minimum is below or above given temperatures.
Trouble isolation
-
Relevant electrical parts
• Fusing unit
• C3922: Heating roller thermistor/Edg (TH1)
• C3925: Heating roller temperature sensor (TEMS)
• C3926: Heating roller thermistor/Ctr (TH2)
• DC power supply (DCPS)
• CPU board (CPUB)
• Base board (BASEB)
Procedure
1.
Check the fusing unit for correct installation (whether it is secured in position).
2.
Check the open/close operation of the right door.
3.
Check the connector between the fusing unit-relay CN3-BASEB CN10E for proper connection and correct as necessary.
4.
Check the connector between the fusing unit-relay CN2-DCPS CN2 for proper connection and correct as necessary.
5.
Check CPUB for proper installation and correct as necessary.
6.
7.
8.
9.
DCPS F102 or FU181 conduction check.
10.
3.9.7 C392B
Contents
Trouble type
C392B: Fusing sensor wire breaks detection (difference of temperature)
Rank
A
Trouble detection condition The difference between the temperature corrected by the heating roller thermistor/Edg (TH1) and the temperature
detected by the heating roller thermistor/Ctr (TH2) exceeds a predetermined value.
Trouble isolation
-
Relevant electrical parts
• Fusing unit
• Heating roller thermistor/Edg (TH1)
• Heating roller thermistor/Ctr (TH2)
• DC power supply (DCPS)
• CPU board (CPUB)
• Base board (BASEB)
Procedure
1.
Check the fusing unit for correct installation (whether it is secured in position).
2.
Check the open/close operation of the right door.
3.
Check the connector between the fusing unit-relay CN3-BASEB CN10E for proper connection and correct as necessary.
4.
Check the connector between the fusing unit-relay CN2-DCPS CN2 for proper connection and correct as necessary.
5.
Check CPUB for proper installation and correct as necessary.
6.
7.
8.
9.
DCPS F102 or FU181 conduction check.
10.
3.10 C4###
3.10.1 C4091
Contents
Trouble type
C4091: Engine communication error
Rank
C
Trouble detection condition Communication with the CTL is interrupted for one min. or longer during a stabilization sequence.
Service Manual
Y119930-3
Summary of Contents for d-Color MF 4003
Page 1: ...Multifunction Digital Copier d Color MF4003 MF3303 Service Manual Version 2 0 Code Y119930 3 ...
Page 48: ...This page is intentionally left blank ...
Page 54: ...This page is intentionally left blank ...
Page 70: ...This page is intentionally left blank ...
Page 76: ...This page is intentionally left blank ...
Page 98: ...This page is intentionally left blank ...
Page 216: ...This page is intentionally left blank ...
Page 354: ...This page is intentionally left blank ...
Page 388: ...This page is intentionally left blank ...
Page 398: ...This page is intentionally left blank ...
Page 570: ...This page is intentionally left blank ...
Page 572: ...This page is intentionally left blank ...
Page 574: ...This page is intentionally left blank ...