d-Color MF4003/MF3303
L TROUBLESHOOTING > 12. PANEL BLACKOUT TROUBLE (BOOT DIAGNOSIS
FUNCTION)
L-118
12.1.2 Manual boot diagnosis procedure
1.
Turn OFF the main power switch under the condition in which the start screen freezes or blacks out during the startup sequence.
2.
Turn the main power switch on while pressing the power key.
3.
After a short beep sound is made once, release the power key and close the front lower door or the front door.
4.
The combination of "power key" and "data indicator" displays the result of the boot diagnosis.
5.
Check the display combination and turn OFF the main power switch.
6.
Perform the procedure according to the result of the boot diagnosis.
12.1.3 Boot diagnosis result list
No.
Power key
Data indicator
Target device
Reason of error
Corrective action procedure
1
Light out
Light out
Control panel
unit
• Control
panel unit
engagement
/mounting
failure
• Control
panel unit
failure
1.
Turn OFF the main power switch and unplug the power cord.
Connect the power cord after 15 sec. or more, and turn ON the
main power switch.
2.
Check the control panel unit for proper installation. Correct the
mounting of control panel unit if faulty.
3.
Reinstall the control panel unit.
4.
Replace the cable for the control panel unit.
5.
Replace the control panel unit.
2
Light up in
purple
Light out
Unable to
determine
• Cable
breakage
• Firmware
abnormality
1.
Turn OFF the main power switch and unplug the power cord.
Connect the power cord after 15 sec. or more, and turn ON the
main power switch.
2.
Check the base board for proper installation. Correct the
mounting of control panel unit if faulty.
3.
Check the CPU board for proper installation. Correct the
mounting of control panel unit if faulty.
4.
Replace the cable for the base board.
5.
6.
3
Light up in
purple
Blink (long
period)
Memory
On-board
memory failure
1.
Turn OFF the main power switch and unplug the power cord.
Connect the power cord after 15 sec. or more, and turn ON the
main power switch.
2.
3.
4
Light up in
purple
Blink (short
period)
Storage board
• Storage
engagement
/mounting
failure
• Storage
failure
1.
Turn OFF the main power switch and unplug the power cord.
Connect the power cord after 15 sec. or more, and turn ON the
main power switch.
2.
Reinstall the storage board.
3.
4.
5.
5
Light up in
purple
Light up
Software
Software trouble
1.
Turn OFF the main power switch and unplug the power cord.
Connect the power cord after 15 sec. or more, and turn ON the
main power switch.
2.
Reinstall the firmware.
3.
Reinstall the storage board.
4.
After that, reinstall the firmware.
5.
6.
NOTE
▪ Perform the troubleshooting in the sequence from step 1 of "Corrective action procedure" against each item while checking that
if each trouble has been resolved. Do not perform the troubleshooting against all troubles at once.
12.1.4 How to reset the boot diagnosis result
1.
Turn OFF the main power switch. Wait for 10 sec. or more, and turn ON the main power switch.
Reboot the machine.
NOTE
▪ The freeze state is reproduced if the cause of the fault has not been eliminated.
Service Manual
Y119930-3
Summary of Contents for d-Color MF 4003
Page 1: ...Multifunction Digital Copier d Color MF4003 MF3303 Service Manual Version 2 0 Code Y119930 3 ...
Page 48: ...This page is intentionally left blank ...
Page 54: ...This page is intentionally left blank ...
Page 70: ...This page is intentionally left blank ...
Page 76: ...This page is intentionally left blank ...
Page 98: ...This page is intentionally left blank ...
Page 216: ...This page is intentionally left blank ...
Page 354: ...This page is intentionally left blank ...
Page 388: ...This page is intentionally left blank ...
Page 398: ...This page is intentionally left blank ...
Page 570: ...This page is intentionally left blank ...
Page 572: ...This page is intentionally left blank ...
Page 574: ...This page is intentionally left blank ...