61
8
MISFEED REMOVAL
When the misfeed (
) indicator blinks or
blinks in the display, the unit will
stop because of a misfeed. If a misfeed occurs when using the SPF, a number may
appear in the display after a minus sign. This indicates the number of the originals
that must be returned to the original feeder tray after a misfeed. Return the required
number of originals. Then this number will disappear when copying is resumed or the
clear (
) key is pressed. When the SPF misfeeds an original sheet, the unit will
stop and the SPF misfeed (
) indicator will blink, while the misfeed (
) indicator
will remain off. For a misfeed of originals in the SPF, see "D: Misfeed in the SPF"
(p.64).
1
Open the side cover.
To open the side cover, see "INSTALLING THE TD CARTRIDGE" (p.10).
2
Check the misfeed location. Remove the misfed paper
following the instructions for each location in the illustration
below. If
blinks in the display, proceed to "A: Misfeed in the
paper feed area" (p.62).
If the unit is turned on with the lower side cover open, the misfeed (
)
indicator will blink. In this case, close the lower side cover. The misfeed
(
) indicator will go out.
3
2
2