2HA/2HB
1-3-31
U099
(cont.)
Method to set or check the original size detection threshold
1. Place an original on the contact glass and turn the original detection switch on. The original size detec-
tion starts and detection data is displayed.
2. Change the detection item using the exposure adjustment keys.
*: See Paper size in U073 for the paper size for each setting.
3. To change the original size detection threshold, light exp. 1, 2 or 3 and change the setting using the
zoom +/- keys.
4. Press the start key. The value is set.
5. Press the stop/clear key. The selected item appears.
Completion
Press the stop/clear key while a selection item is displayed. The indication for selecting a maintenance item
No. appears.
U100
Setting the main high voltage
Description
Changes the surface potential by changing the grid control voltage. Also performs main charging. Also
changes the setting of main charging copy quantity correction.
Purpose
To set the surface potential or check main charging. Also used when reentering data after initializing the set
data.
Start
1. Press the start key.
2. Select the item using the exposure adjustment keys.
Method for main charger output
1. Press the start key. The selected operation starts.
2. To stop operation, press the stop/clear key.
Setting the grid control voltage
1. Change the setting using the zoom +/- keys.
Increasing the setting makes the surface potential higher, and decreasing it makes the potential lower.
Change in value per step: approximately 3.6 V
2. Press the start key. The value is set.
Maintenance
item No.
Description
Exposure
indicator
Description
Data range
Initial
setting
Exp. 1
Scanner data threshold
0 to 255
170
Exp. 2
Time between original detection switch
turning on and reading-in of scanner data
0 to 100 ms
30
Exp. 3
Detected width for A4R
220/240 mm
240
Exp. 4
Detected original width
0 to 350 mm
-
Exp. 5
Original size detected by scanner data and
original size sensor detection data
0 to 63*
-
Exposure indicator
Description
Exp. 1 (lit)
Changing the grid control voltage
Exp. 2 (lit)
Turning the main charger on
Exp. 3 (lit)
Turning the main charger on and the laser scanner unit on and off
Exp. 4 (lit)
Main charging copy quantity correction, copy interval
Exp. 5 (lit)
Main charging copy quantity correction, copy quantity
Exp. 1 (flashing)
Main charging copy quantity correction, correction amount
Description
Setting range
Initial setting
Grid control voltage
0 to 255
132
Summary of Contents for d-Copia 1600
Page 1: ...SERVICE MANUAL Published in October 2005 842HB110 First Edition d Copia 1600 d Copia 2000...
Page 3: ...Revision history Revision Date Replaced pages Remarks...
Page 4: ...This page is intentionally left blank...
Page 10: ...This page is intentionally left blank...
Page 14: ...2HA 2HB 1 4 30 This page is intentionally left blank...
Page 20: ...2HA 2HB 1 4 30 This page is intentionally left blank...
Page 126: ...2HA 2HB 1 4 30 This page is intentionally left blank...
Page 162: ...2HA 2HB 1 4 30 This page is intentionally left blank...
Page 180: ...2HA 2HB 1 4 30 This page is intentionally left blank...
Page 213: ...INSTALLATION GUIDE FOR THE 300 SHEET CASSETTE...
Page 220: ...INSTALLATION GUIDE FOR THE DOCUMENT PROCESSOR...
Page 231: ...INSTALLATION GUIDE FOR THE DUPLEX UNIT...
Page 239: ...INSTALLATION GUIDE FOR THE Printing System X...
Page 242: ......