1-3-58
U425
Set Target
Description
Enters the lab values that is indicated on the back of the chart (P/N:
AVGR23234P
) used
for adjustment.
Purpose
Performs data input in order to correct for differences in originals during automatic adjustment.
Method
1. Press the start key.
2. Select the item to be set.
Display
Description
Table
Setting the value of the table adjustment.
DP
Setting the value of DP adjustment.
Method: Table
1. Press the start key.
2. Select the item to be set.
Display
Description
White
Setting the white patch for the original for adjustment
Black
Setting the black patch for the original for adjustment
Gray1
Setting the Gray1 patch for the original for adjustment
Gray2
Setting the Gray2 patch for the original for adjustment
Gray3
Setting the Gray3 patch for the original for adjustment
C
Setting the cyan patch for the original for adjustment
M
Setting the magenta patch for the original for adjustment
Y
Setting the yellow patch for the original for adjustment
R
Setting the red patch for the original for adjustment
G
Setting the green patch for the original for adjustment
B
Setting the blue patch for the original for adjustment
Adjust Original
Setting the main and auxiliary scanning directions
3. Select the item to be set.
Display
Description
Setting range
Initial setting
L
Setting the L value
0.0 to 100.0
93.6/10.6/76.2/25.2/51.3
72.6/48.1/86.2/46.7/67.8/38.8
a
Setting the a value
-200.0 to 200.0
0.9/-0.2/-0.2/-0.2/-0.3
-32.8/69.9/-18.6/54.2/-51.3/25.3
b
Setting the b value
-200.0 to 200.0
-0.4/-0.7/1.2/-0.2/0.3
-11.5/-6.1/81.7/38.6/48.9/-22.8
4. Enters the value that is indicated on the face of the chart using the cursor right/left keys or
numeric keys.
5. Press the start key. The value is set.
Service Manual
Y116540
-5
Summary of Contents for d-Copia 4003MF
Page 11: ...This page is intentionally left blank...
Page 52: ...1 2 24 This page is intentionally left blank Service Manual Y116540 5...
Page 384: ...1 5 100 This page is intentionally left blank Service Manual Y116540 5...
Page 484: ...Installation Guide PF 320 Paper Feeder Installation Guide...
Page 486: ...For Legal Folio OficioII 1 1 1 1 2 2 2 2...
Page 487: ...UPDATINGSTATUS DATE UPDATEDPAGES PAGES CODE 03 2015 1ST EDITION 487 Y116540 5...