1-3-25
Service Manual
Y116
540-5
5. Change the setting value using the cursor right/left keys or numeric keys.
For output example 1, increase the value. For output example 2, decrease the value
example 1
Figure 1-3-4
6. Press the start key. The value is set.
Caution
Check the copy image after the adjustment. If the image is still incorrect, perform the following
adjustments in maintenance mode.
U034 -------- U066 -------- U071
Adjustment: LSU Out Left
1. Press the system menu key.
2. Press the start key to output a test pattern.
3. Press the system menu key.
4. Select the item to be adjusted.
[LSU Out Left]
Display
Description
Setting
range
Initial
setting
Change in
value per step
Left
0 to 1180
642
1 dot
MPT
-70 to 70
-14
1 dot
Cass1
-70 to 70
0
1 dot
Cass2
-70 to 70
0
1 dot
Cass3
-70 to 70
0
1 dot
Cass4
-70 to 70
0
1 dot
Cass5
-70 to 70
0
1 dot
Dup
The standard value of Center line
Paper feed from MP tray.
Paper feed from cassette1.
Paper feed from optional cassette2.
Paper feed from optional cassette3.
Paper feed from optional cassette4.
Paper feed from optional cassette5.
Duplex mode. (second)
-70 to 70
-4
1 dot
Correct image
Output
Output
example 2
Leading edge
registration
(20 ± 1.0 mm)
Summary of Contents for d-Copia 4003MF
Page 11: ...This page is intentionally left blank...
Page 52: ...1 2 24 This page is intentionally left blank Service Manual Y116540 5...
Page 384: ...1 5 100 This page is intentionally left blank Service Manual Y116540 5...
Page 484: ...Installation Guide PF 320 Paper Feeder Installation Guide...
Page 486: ...For Legal Folio OficioII 1 1 1 1 2 2 2 2...
Page 487: ...UPDATINGSTATUS DATE UPDATEDPAGES PAGES CODE 03 2015 1ST EDITION 487 Y116540 5...