1-3-30
U067
Table Center
Description
Adjusts the scanner center line of the original scanning.
Purpose
Make the adjustment if there is a regular error between the center lines of the copy image and
original.
Adjustment
1. Press the start key.
2. Press the system menu key.
3. Place an original and press the start key to make a test copy.
4. Press the system menu key.
5. Select the item to be adjusted.
Display
Description
Setting
range
Initial
setting
Change in
value per step
Front
Scanner center line
-60 to 60
0
0.085 mm
Rotate
Scanner center line (rotate copying)
-40 to 40
0
0.085 mm
6. Change the setting value using the cursor right/left keys or numeric keys.
For copy example 1, decrease the value. For copy example 2, increase the value.
Increasing the value moves the image leftward and decreasing it moves the image rightward.
Figure 1-3-8
7. Press the start key. The value is set.
Caution
If the above adjustment does not optimize the center line, proceed with the following maintenance
modes.
U034 --------- U065 --------- U067
Completion
Press the stop key. The screen for selecting a maintenance item No. is displayed.
Center line of the copy image (within ± 2.0 mm)
Original
Copy
example 1
Copy
example 2
Service Manual
Y116540
-5
Summary of Contents for d-Copia 4003MF
Page 11: ...This page is intentionally left blank...
Page 52: ...1 2 24 This page is intentionally left blank Service Manual Y116540 5...
Page 384: ...1 5 100 This page is intentionally left blank Service Manual Y116540 5...
Page 484: ...Installation Guide PF 320 Paper Feeder Installation Guide...
Page 486: ...For Legal Folio OficioII 1 1 1 1 2 2 2 2...
Page 487: ...UPDATINGSTATUS DATE UPDATEDPAGES PAGES CODE 03 2015 1ST EDITION 487 Y116540 5...