1-4-72
(17) Abnormal image
1. Table scanning
2. DP-scanning
Print example
Defective part
Check description
Corrective Action
1
FFC cable CCD
Check the FFC cable between
the CCD and control PWB is
properly connected. Or, verify
conduction of the wire.
Reinsert the connector if its connection is
loose. Or, if conduction is lot, replace the wire.
2
CCD PWB
The CCD PWB is defective.
Replace the ISU and perform U411.
(see page 1-3-54)
3
Control PWB
The control PWB is defective.
Replace the control PWB.(see page 2-2-12)
Defective part
Check description
Corrective Action
1
FFC cable CCD
Check the FFC cable between
the CCD and control PWB is
properly connected. Or, verify
conduction of the wire.
Reinsert the connector if its connection is
loose. Or, if conduction is lot, replace the wire.
2
CCD PWB
The CCD PWB is defective.
Replace the ISU and perform U411.
(see page 1-3-54)
3
Control PWB
The control PWB is defective.
Replace the control PWB.(see page 2-2-12)