1-4-76
(2) No image appears (entirely black).
Print example
Cause of trouble
1. No main charging.
2. The laser from the LSU is activated simultaneously.
Defective part
Check description
Corrective Action
1
Charging roller
Check whether the charging
roller is properly mounted.
If the charging roller is not fixed properly, fix the
roller properly.
Check whether the connecting
terminals of the charging roller
and high-voltage PWB are
deformed.
If the connecting terminals are deformed,
correct for a proper conduction.
2
High voltage PWB
Check the connection of the con-
nectors. Or, verify conduction of
the wires.
Reinsert the connector if its connection is
loose.
Replace the cable if it has no conduction.
High voltage PWB (YC101) and control PWB
(YC19) :Charger
Main charging current supplied
by the high voltage PWB is
faulty.
Replace the high voltage PWB.
(see page 2-2-20)
3
Laser scanner unit
(LSU)
Switching on and off the laser
diode on the LSU PWB is out of
control.
Replace the LSU. (see page 1-5-25)
4
Control PWB
The control PWB is detective.
Replace the control PWB.(see page 2-2-12)
Service Manual
Y116540
-5
Summary of Contents for d-Copia 4003MF
Page 11: ...This page is intentionally left blank...
Page 52: ...1 2 24 This page is intentionally left blank Service Manual Y116540 5...
Page 384: ...1 5 100 This page is intentionally left blank Service Manual Y116540 5...
Page 484: ...Installation Guide PF 320 Paper Feeder Installation Guide...
Page 486: ...For Legal Folio OficioII 1 1 1 1 2 2 2 2...
Page 487: ...UPDATINGSTATUS DATE UPDATEDPAGES PAGES CODE 03 2015 1ST EDITION 487 Y116540 5...