2-2-31
(4) Detaching and refitting the PWB. (CRPWB)
Procedure
1. Remove the upper interface cover.
2. Release two hooks using a flat screw
driver and remove the right stay cover.
Figure 2-2-30
3. Remove the controller cover.
4. Open the front cover.
5. Remove the screw from the right upper
cover.
6. Release two hooks using a flat screw
driver and remove the right upper cover.
Figure 2-2-31
Upper
interface cover
Flat screw driver
Right stay cover
Hooks
Controller cover
Flat screw driver
Hooks
Right upper cover
Screw