3K5
2-3-4
YC7
1
24V
O
24 V DC
24 V DC supply
Connected
to the
switchback
presser
solenoid
and switch-
back feed-
shift
solenoid.
2
ACT
O
0/24 V DC
SBPSOL (ACT): On/Offd
3
RET
O
0/24 V DC
SBPSOL (RET): On/Off
4
24V
O
24 V DC
24 V DC supply
5
ACT
O
0/24 V DC
SBFSSOL: On/Off
YC8
1
LED_RD
O
2.1/0 V DC
OSLEDPWB (red): On/Off
Connected
to the origi-
nal set LED
PWB.
2
GND
-
-
Ground
3
LED_GN
O
2.1/0 V DC
OSLEDPWB (green): On/Off
4
N.C.
-
-
Not used
YC9
1
5V
O
5 V DC
5 V DC supply
Connected
to the origi-
nal switch-
back switch,
original size
length
switch and
original size
width switch.
2
REV SW
I
0/5 V DC
OSBSW: On/Off
3
GND
-
-
Ground
4
SZ_SW_L
I
0/5 V DC
OSLSW: On/Off
5
5V
O
5 V DC
5 V DC supply
6
GND
-
-
Ground
7
SZ_SW_W
I
Analog
OSWSW: On/Off
8
5V
O
5 V DC
5 V DC supply
YC10
1
GND
-
-
Ground
Connected
to original
set switch.
2
SET SW
I
0/5 V DC
OSSW: On/Off
3
5V
O
5 V DC
5 V DC supply
YC11
1
5V
O
5 V DC
5 V DC supply
Connected
to DP cool-
ing fan
motor.
2
N.C.
-
-
Not used
3
N.C.
-
-
Not used
4
N.C.
-
-
Not used
5
GND
-
-
Ground
Connector
Pin No.
Signal
I/O
Voltage
Description
Service Manual Y108671-9
Summary of Contents for DP-670
Page 1: ...DP 670 DP 670 B Option Copier SERVICE MANUAL Code Y108671 9 ...
Page 4: ...This page is intentionally left blank ...
Page 10: ...This page is intentionally left blank ...
Page 16: ...3K5 1 1 4 This page is intentionally left blank Service Manual Y108671 9 ...
Page 20: ...3K5 1 2 4 This page is intentionally left blank Service Manual Y108671 9 ...
Page 68: ...3K5 1 3 48 This page is intentionally left blank Service Manual Y108671 9 ...
Page 86: ...3K5 1 6 4 This page is intentionally left blank Service Manual Y108671 9 ...
Page 90: ...3K5 2 1 4 This page is intentionally left blank Service Manual Y108671 9 ...
Page 103: ...UPDATINGSTATUS DATE UPDATEDPAGES PAGES CODE 06 2010 1ST EDITION 103 Y108671 9 ...