3JX
1-3-13
U411
Adjusting the scanner automatically
Description
Uses a specified original and automatically adjusts the following items in the scanner and the DP scanning
sections.
Purpose
To perform automatic adjustment of various items in the scanner and the DP scanning sections.
Method
1. Press the start key.
2. Select the item. The screen for executing is displayed.
Remarks
Cut the trailing edge of the original as shown when the specified original (P/N:
AVGR05132X
) is used.
Figure 1-3-7
Method: SCANNER
1. Enter the target values which are shown on the specified original (
P/N:
AVGR05131K
) executing mainte-
nance item U425.
2. Set a specified original (P/N:
AVGR05131K
) on the platen.
3. Select the item.
4. Press the start key. Auto adjustment starts.
When automatic adjustment has normally completed, [RESULT OK 00] is displayed. If a problem occurs
during auto adjustment, [ERROR XX] (XX is replaced by an error code) is displayed and operation
stops. Should this happen, determine the details of the problem and either repeat the procedure from
the beginning, or adjust the remaining items manually by running the corresponding maintenance items.
5. To return to the screen for selecting an item, press the stop key.
Maintenance
item No.
Description
Display
Description
Original to be used for
adjustment (P/N)
SCANNER Automatic adjustment in the scanner section
AVGR05131K
DP(FACE UP)
Automatic adjustment in the DP scanning
section (first page)
AVGR05132X
DP(FACE DOWN)
Automatic adjustment in the DP scanning
section (second page)
AVGR05132X/AVGR05133T/
AVGR05134Q
128 1mm
+
-
+
-
60 1mm
Cut with the edge of black belt.
Display
Description
ALL
Automatic adjustment using the platen for: original size magnification/leading
edge timing/center line, input gamma, chromatic aberration filter, MTF filter
and matrix.
INPUT
Automatic adjustment using the platen for: original size magnification/leading
edge timing/center line.
GAMMA
Automatic adjustment using the platen for: input gamma.
C.A.
Automatic adjustment using the platen for: chromatic aberration filter.
MTF
Automatic adjustment using the platen for: MTF filter.
MATRIX
Automatic adjustment using the platen for: matrix.
Y106871-5 Service Manual
Summary of Contents for DP-700
Page 1: ...DP 700 Copier SERVICE MANUAL Code Y106871 5...
Page 11: ...3JX 1 1 4 This page is intentionally left blank Service Manual Y106871 5...
Page 15: ...3JX 1 2 4 This page is intentionally left blank Service Manual Y106871 5...
Page 49: ...3JX 1 5 8 This page is intentionally left blank Service Manual Y106871 5...
Page 55: ...3JX 2 2 4 This page is intentionally left blank Service Manual Y106871 5...
Page 75: ...3JX 2 4 4 This page is intentionally left blank Service Manual Y106871 5...
Page 76: ...UPDATINGSTATUS DATE UPDATEDPAGES PAGES CODE 10 2006 1ST EDITION 76 Y106871 5...