3JX
1-5-4
(2) Detaching and refitting the DP separation pulley
Follow the procedure below to replace the DP separation pulley.
Procedure
1. Open the top cover.
2. Release the inserted part and then remove
the separation guide.
Figure 1-5-6
3. Remove the stop ring and then DP separa-
tion pulley and torque limiter.
4. Replace the DP separation pulley and install
the pulley to the DP.
Figure 1-5-7
Separation guide
Inserted part
DP separation pulley
Stop ring
Torque limiter